FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Software to be supplied with GX Works3
GX Works2 and GX Developer are supplied with GX Works3. When installing GX Works3, you can select whether to install GX Works2 and GX Developer together. More Details >>
- No:22463
- Release Date:2018/09/03 17:28
- Update:2018/09/18 16:14
- Category: MELSEC iQ-R Series
-
Regarding the controller Line-up
The MX-F Model has the following features. More Details >>
- No:44964
- Release Date:2025/05/08 09:06
- Category: MELSEC MX Controller MX-F Model
-
Regarding performing Data Logging with Special Relays
It's possible. Using special relays, it is possible to perform data logging from a program. For details, see the manual below. MELSEC iQ-F FX5 User's Manu... More Details >>
- No:39327
- Release Date:2023/02/14 09:05
- Category: MELSEC iQ-F Series , CPU Module
-
SB/SW refresh device setting with CC-Link
SB/SW uses 512 points of refresh devices. More Details >>
- No:23081
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Limitation on the number of levels of cascade connections when QJ71E71-100 is used
If a repeater hub is used, 10BASE-T allows a maximum of four levels of cascade connections and 100BASE-TX allows a maximum of two levels of cascade connectio... More Details >>
- No:23040
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Links with a CC-Link local station cannot be made
Check the following points. (1) CC-Link cables have been properly connected. (2) Station numbers and the transmission speed have been correctly set. (3)... More Details >>
- No:23033
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:22
- Category: Network related products
-
Effect on sequence scans in MELSECNET/H networks
It is necessary to reduce the link refresh time of the MELSECNET/H network in order to reduce the scan time. The link refresh time can be reduced by reducin... More Details >>
- No:23018
- Release Date:2018/09/03 17:31
- Update:2018/09/26 09:27
- Category: Network related products
-
Reception data read request signal of QJ71C24N not turn ON
The default receive complete code is CR+LF (0DH, 0AH). The default received data count is 511 words. Hence, at their defaults, Reception data read request si... More Details >>
- No:22984
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:22
- Category: Network related products
-
The number of CC-Link modules mountable with a universal model QCPU module
If the parameter is set, the following number of modules can be mounted at maximum. - Q00UJ/Q00U/Q01UCPU: Up to 2 modules - Q02UCPU: Up to 4 modules - Uni... More Details >>
- No:22981
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:20
- Category: Network related products
-
Difference in specifications between CC-Link versions
Ver.1.10 is a standard where CC-Link station-to-station cable length restriction in Ver. 1.00 has been removed, and the length of all station-to-station cabl... More Details >>
- No:22975
- Release Date:2018/09/03 17:31
- Category: Network related products
901-910 of Total 1110