FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Communication between CPU modules established by QJ71E71
The communication between QJ71E71 series modules can be established if READ/WRITE instructions are used. More Details >>
- No:23036
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Assigning X and Y signals of AJ65SBTB1-32DT
X and Y assignments are as follows.- X0 to XF- Y10 to Y1F More Details >>
- No:23034
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link signals checked when an error occurs
Check the following signals.- Module error signal : X0- Host data link status signal: X1- Other station data link status signal: X3 More Details >>
- No:23021
- Release Date:2018/09/03 17:31
- Category: Network related products
-
For CPU modules with 8192 I/O device points (X/Y0 to 1FFF), X/Y1000 and greater can be set as refresh devices. More Details >>
- No:23014
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Terminating resistors for RS-485 communication of LJ71C24
The resistance value is 110 ohm, 1/2 W. More Details >>
- No:22999
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:25
- Category: Network related products
-
Difference between AJ65SBTB1-32DT and AJ65SBTB1-32DT2
Major differences are shown below. - AJ65SBTB1-32DT- Leakage current at OFF 0.25 mA or lower- Protection function (overload protection, overvoltage protectio... More Details >>
- No:22985
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How refresh devices for CC-Link remote inputs and outputs are assigned
The refresh device setting of the CC-Link parameter assigns any devices to the I/O numbers greater than those assigned to the modules on the same base unit. ... More Details >>
- No:22968
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CW Workbench can be purchased from Mitsubishi Electric. We also accept license applications. More Details >>
- No:22880
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Index modification when using extended data register in LCPU
It is not possible to specify index modification to cross over the boundary between the internal user device (D) and the extended data register (D). Change t... More Details >>
- No:22822
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Restriction on the use of CPU when branch module and extension module are used
Use L series CPU modules whose first 5 digits of the serial number are "13072" or later. More Details >>
- No:22800
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
901-910 of Total 1123