FAQ
FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Auto refresh setting in GX Configurator -MB
Auto refresh setting is for storing the buffer memory data of a MODBUS (R) interface module to specified devices of a CPU module and for storing device data ... More Details >>
- No:22573
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Using Structured Text in GX Works2 simple projects
Select "Use Label" in the New Project window. More Details >>
- No:22562
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Difference between FL-net interface modules QJ71FL71-T and QJ71FL71-T-F01
- QJ71FL71-T is a product which supports FL-net (OPCN-2) Version 1.00.- QJ71FL71-T-F01 is a product which supports FL-net (OPCN-2) Version 2.00.Since Version... More Details >>
- No:22551
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Specification method of high-speed timer
To use a high-speed timer, insert a circuit of application instruction such as "OUTH T0 K100". More Details >>
- No:22549
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Turning OFF the power with the battery error occurring
It deletes the error history. More Details >>
- No:22545
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Those displayed under COMMENT are common comments, and others are program comments.When there are multiple programs in a project, a common comment applies to... More Details >>
- No:22540
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
GX Developer installation procedure from the iQ Works disk
Use setup.exe in the [GXD1] folder of the installation disk to install the application. More Details >>
- No:22532
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Behavior of special relay in simulation
The constant scan initial value in the simulation function is 100ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set ... More Details >>
- No:22521
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:23
- Category: MELSEC-Q Series
-
Although it depends on interrupt factors, the overhead time before startup becomes 10.8 to 23.8 [us] and the time after startup becomes 6.5 to 17.4 [us]. More Details >>
- No:22499
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:14
- Category: MELSEC iQ-R Series
-
Inter-module synchronization function of MELSEC iQ-R series
The inter-module synchronization function synchronizes the timing to control signals of multiple modules. This function synchronizes the input or output tim... More Details >>
- No:22497
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:21
- Category: MELSEC iQ-R Series
901-910 of Total 1055