FAQ
![](/usr/file/attachment/q&a.jpg)
![](/usr/file/attachment/q&a_sp.jpg)
FAQAbout Products
![](/usr/file/attachment/img_mv-1_sm.jpg)
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Causes to why SD1286 does not turn on during socket communication of LCPU
Check the following. - Whether the external device specifies the port number of the corresponding connection to the L series CPU. - In the TCP fixed-length... More Details >>
- No:22787
- Release Date:2018/09/03 17:30
- Update:2018/09/22 11:51
- Category: MELSEC-L Series
-
Q6BAT. More Details >>
- No:22780
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
LCPU internal clock synchronization
Use the time setting function to synchronize the internal clock. More Details >>
- No:22755
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
LCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices.- Protocol: "UDP"- Open System: "MELSOFT connection" More Details >>
- No:22739
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Communication data code of the MC protocol for the built-in Ethernet port in LCPU
The communication data code is selectable by the communication data code setting in [Parameter] -> [PLC Parameter] -> [Built-in Ethernet Port Setting]. More Details >>
- No:22735
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:22
- Category: MELSEC-L Series
-
Pulse width with which the QX42 recognizes all pulses
Maximum scan time (10 ms) + Response time (10 ms) = Pulse width with which the module recognizes all pulses (20 ms) More Details >>
- No:22720
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to launch GX Works2 or other tools after installing iQ Works
The tools can be launched individually. More Details >>
- No:22693
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
What to do in the case of the error "A default router IP address needs to be set."
When having access bypassing a router, enter only the IP address.The subnet mask pattern is not required to be entered because GX Works2 or GX Developer auto... More Details >>
- No:22605
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:06
- Category: MELSEC-Q Series
-
Life expectancy of the CompactFlash card used in the high speed data logger module
The life expectancy is determined by the following calculation.Life expectancy (year) = Total writable size (GB) / 1 year write size (GB/year)For more detail... More Details >>
- No:22592
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
"No administrator authority" warning displayed in MX Component
The user account control (UAC) setting needs to be changed.For more details, refer to Appendix 8.2 of the following manual.- MX Component Version 3 Operating... More Details >>
- No:22590
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
911-920 of Total 1055