Number of extension cables that can be used per system
One extension cable can be used per system. Two or more extension cables cannot be used. More Details >>
- No:24958
- Release Date:2019/04/18 14:33
- Category: MELSEC-F Series
-
It takes 1 ms or less in a unit of the motor system and 2 ms or less in a unit of the machine system. * Motor system∙∙∙The pulse number is used as the stand... More Details >>
- No:24943
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Positioning Control
-
Modules that support differential line driver outputs
The FX3U-2HSY-ADP, FX2N-10PG support differential line driver outputs. More Details >>
- No:24691
- Release Date:2019/02/27 08:56
- Update:2023/02/15 13:09
- Category: MELSEC-F Series , Positioning Control
-
Refresh timing of bit data and word data in the same CC-Link station
Cyclic data is sometimes separated into new and old data by two words (32 bits) with auto refresh timing. Checking "Block data assurance per station" of the ... More Details >>
- No:23058
- Release Date:2018/09/03 17:31
- Category: Network related products
-
What makes the ERR LED flash in a CC-Link network
A link error has occurred in one of the slave stations in connection.Master station: Check the parameter again.Slave station: Reassess the power supply, the ... More Details >>
- No:23023
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Clearing data in the QJ71C24N's receiving area buffer memory
Receiving data overwrites the buffer memory data. Writing 0 with a program can be performed but is unnecessary as the data is overwritten. More Details >>
- No:23009
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link master module settings
If each master module controls their own CC-Link networks, all master modules can be set as station 0 even though they are controlled by the same CPU. More Details >>
- No:23008
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Difference between the CC-Link IE Controller Network and a MELSECNET/H network
The CC-Link IE Controller Network is an improved system that has a higher processing speed and a larger data capacity than the MELSECNET/H network system (PL... More Details >>
- No:22979
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:17
- Category: Network related products
-
Specifying the number of digits in the Structured Text
For actual bit devices, the number of digits can be specified. For labels, the number of digits cannot be specified. More Details >>
- No:22891
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual C++ .NET 2003
MX Component Version 4 does not support Visual C++ .NET 2003. More Details >>
- No:22874
- Release Date:2018/09/03 17:30
- Category: Engineering Software