SD520 stores the current scan time in 1 ms units. More Details >>
- No:22556
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
The duplicated coil error is detected when SET instruction and RST instruction use the same device. More Details >>
- No:22534
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
GX Developer installation procedure from the iQ Works disk
Use setup.exe in the [GXD1] folder of the installation disk to install the application. More Details >>
- No:22532
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Regarding differences between instance communication and tag communication
Instance communication ・The instance ID (any number) is used to communicate with the other device. Tag communication ・The tag name (any character string) ... More Details >>
- No:45486
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding understanding FX5-EIP Configuration Restrictions
One FX5-EIP can be used per system. It cannot be used with FX5-ENET/IP. More Details >>
- No:45484
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding EtherNet/IP communication function for FX5-EIP
The following EtherNet/IP communication functions are supported by the FX5-EIP. ・Cyclic communication function ⇒Class1 instance communication/tag communicat... More Details >>
- No:45483
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>
- No:45477
- Release Date:2025/11/12 13:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding replacement from 128 point type of FX3U
The FX5U CPU module has a lineup of up to 80 point. The following configuration is recommended when replacing the FX3U-128MR/ES. Recommended alternative (1... More Details >>
- No:44617
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module
-
CC-Link IE field When a network such as Network Basic is interrupted, the CPU module does not stop and continues to run. When the CC-Link IE Field Network i... More Details >>
- No:44611
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding Selecting a mapping pattern for PDO communication
On the FX5-CCLGN-MS, select "3rd Transmit PDO Mapping" and "3rd Revive PDO Mapping." The 3rd mapping pattern corresponds to the profile position mode (pp), ... More Details >>
- No:44477
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication