The automatic communication function and dedicated instructions (MBRW instruction and MBREQ instruction) can be used on the same channel. However, when the... More Details >>
- No:22577
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:06
- Category: MELSEC-Q Series
-
How to read device data and file registers in Q series
Specify the target memory in the Read from PLC window and execute reading. More Details >>
- No:22564
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Reading file registers in the standard RAM
Set Target Memory to "Standard RAM" in the Read from PLC window to select a file register file. More Details >>
- No:22552
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Difference between QH42P and QX41Y41P
The difference is I/O numbers used for input and output (XY). QH42P uses the same I/O numbers both for input and output. QX41Y41P uses sequential I/O numbers... More Details >>
- No:22539
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Using Q series terminal blocks and connectors with MELSEC iQ-R series modules
You can use a Q series 18-point screw terminal block with a MELSEC iQ-R series terminal block type I/O module or analog module. For a 40-pin connector type ... More Details >>
- No:22474
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:37
- Category: MELSEC iQ-R Series
-
Regarding maintaining device back up
Battery: FX3U-32BL is not required for device back up.The battery is used to store clock data. More Details >>
- No:44976
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Regarding the built-in motion function
The built-in motion function of the MX-F Model is programmed using motion control FB, wheareas the FX5-40/80SSC-G of the iQ-F series is programmed using buff... More Details >>
- No:44970
- Release Date:2025/06/18 14:38
- Category: MELSEC MX Controller MX-F Model
-
Regarding reuse of GOT connector cable when replacing with FX5 CPU module
The connection cable is GT01-C30R4-8P. The FX5U CPU module does not have an RS422 port, so you will need to add an FX5-422-BD-GOT. More Details >>
- No:44615
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding restrictions on the external input/output forced ON/OFF function
The following restrictions apply to the external input/output forced ON/OFF function. ・Since RUN contact setting is RUN/STOP by external signal, forced ON/O... More Details >>
- No:44332
- Release Date:2024/03/20 12:58
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding device comment output to Data Logging Files
Device comments can not be output to data logging files. More Details >>
- No:39321
- Release Date:2023/02/14 09:00
- Category: MELSEC iQ-F Series , CPU Module
941-950 of Total 1123