Update timing of LD75 current feed value and machine feed value
The values are updated at the timing described below. - Current feed value: 0.9 ms - Machine feed value: 0.9 ms More Details >>
- No:22748
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Configuration of simple PLC communication function using LCPU
At least one L series CPU is necessary when using the simple PLC communication function. More Details >>
- No:22747
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Communication between CPUs via built-in Ethernet port in LCPU
The following communication methods are available between the built-in Ethernet ports in the L series CPUs.- Simple PLC communication function- Socket commun... More Details >>
- No:22746
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Difference between L02CPU-P and L02CPU
In L02CPU-P, the general-purpose output of the built-in I/O is source type. In L02CPU, the general-purpose output of the built-in I/O is sink type. More Details >>
- No:22743
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
L63P compatibility with L series CPU packages
It is possible to remove L61P and use L63P. More Details >>
- No:22742
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Simultaneous use of simple PLC communication function and socket communication
The socket communication can be used simultaneously with the simple PLC communication function. More Details >>
- No:22740
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Turning OFF the power with the battery error occurring
The error history will be deleted. More Details >>
- No:22734
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
MC protocol compatibility of the built-in Ethernet port
The built-in Ethernet port is not compatible with a 4E frame. Use a QnA-compatible 3E frame. More Details >>
- No:22732
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Hardware setting for using Q series extension base units
You need to set the number of extension base units with the connector for setting the number of extension base units.For details, refer to the following.SH-0... More Details >>
- No:22721
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Pulse width with which the QX42 recognizes all pulses
Maximum scan time (10 ms) + Response time (10 ms) = Pulse width with which the module recognizes all pulses (20 ms) More Details >>
- No:22720
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series