Regarding number of occupied I/O points of intelligent function module
The number of occupied input/output points per module is 8. (Excluding some models) Occupied I/O points: Since actual occupied I/O points cannot be assigned... More Details >>
- No:44612
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Input Response Frequency Difference between FX5-2HC/ES and Conventional Model (FX3U-2HC)
The input response frequencies of the FX5-2HC/ES and FX3U-2HC differ as shown below. FX5-2HC/ES・・・2MHz FX3U-2HC・・・200kHz More Details >>
- No:44340
- Release Date:2024/03/20 13:31
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Output frequency of the FX3U-1PG pulse output block
It is from 1 Hz to 200 kHz. More Details >>
- No:24981
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Positioning Control
-
Communication between CPU modules established by QJ71E71
The communication between QJ71E71 series modules can be established if READ/WRITE instructions are used. More Details >>
- No:23036
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Executing the QJ71C24N's pre-defined protocol support function
Executing the CPRTCL instruction (dedicated instruction) executes a specified protocol. More Details >>
- No:23004
- Release Date:2018/09/03 17:31
- Category: Network related products
-
QJ71E71-100's compatibility with the automatic cable type (straight or cross) recognizing function
QJ71E71-100 does not support the AutoMDI/MDI-X function (automatic cable type (straight or cross) recognizing feature). More Details >>
- No:22976
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Difference in specifications between CC-Link versions
Ver.1.10 is a standard where CC-Link station-to-station cable length restriction in Ver. 1.00 has been removed, and the length of all station-to-station cabl... More Details >>
- No:22975
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Behavior of special relay in offline simulation
The constant scan initial value of GX Simulator is 100 ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set the consta... More Details >>
- No:22922
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:39
- Category: Engineering Software
-
If MX Sheet that supports Excel2010 is installed, the data can be used as they are. More Details >>
- No:22892
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Copying statements and notes of GX Developer
Notes and statements are batch managed in the program file. It is impossible to copy notes and statements alone. More Details >>
- No:22853
- Release Date:2018/09/03 17:30
- Category: Engineering Software