FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19
- Category: MELSEC iQ-F Series , Network/Communication
-
You can insert and remove the extended SRAM cassette less than 50 times and the SD memory card less than 500 times. More Details >>
- No:22470
- Release Date:2018/09/03 17:28
- Category: MELSEC iQ-R Series
-
Using Q series terminal blocks and connectors with MELSEC iQ-R series modules
You can use a Q series 18-point screw terminal block with a MELSEC iQ-R series terminal block type I/O module or analog module. For a 40-pin connector type ... More Details >>
- No:22474
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:37
- Category: MELSEC iQ-R Series
-
IP filter function of MELSEC iQ-R series CPU modules
You can set IP addresses accessible to the CPU module and prevent unauthorized access to the CPU module. <Setting the IP filter function> [Navigati... More Details >>
- No:22479
- Release Date:2018/09/03 17:28
- Update:2018/09/19 15:01
- Category: MELSEC iQ-R Series
-
Although it depends on interrupt factors, the overhead time before startup becomes 10.8 to 23.8 [us] and the time after startup becomes 6.5 to 17.4 [us]. More Details >>
- No:22499
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:14
- Category: MELSEC iQ-R Series
-
How to read projects created by GX Works2 in GX Developer
Select [Project] -> [Export to GX Developer Format File] and save the project so that it can be opened in GX Developer.For more details, refer to GX Works... More Details >>
- No:22515
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
MX Component Version 3's compatibility with 64-bit Windows 7
MX Component Version 3.15R or later supports 64-bit Windows 7. More Details >>
- No:22520
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Behavior of special relay in simulation
The constant scan initial value in the simulation function is 100ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set ... More Details >>
- No:22521
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:23
- Category: MELSEC-Q Series
-
Usage of PIDCONT instruction in process CPU
No. More Details >>
- No:22536
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Difference between C Controller module and programmable controller CPU module
- C Controller module: Programs are created using C and C++ languages. The programs run based on each task and parallel processing of multiple tasks base... More Details >>
- No:22542
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:05
- Category: MELSEC-Q Series
1-10 of Total 1082