Controllers
FAQ within [ Controllers ]
-
The power supply lamp of a running programmable controller suddenly turned off or flashes
Check whether the lamp is back to normalafter disconnecting the wiring of the "24V" (service power supply) terminal. Ifthe lamp is back to normal,the servic... More Details >>
- No:22267
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:53
- Category: MELSEC-F Series , Main Unit
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
You can insert and remove the extended SRAM cassette less than 50 times and the SD memory card less than 500 times. More Details >>
- No:22470
- Release Date:2018/09/03 17:28
- Category: MELSEC iQ-R Series
-
Processing time of when multiple programs are executed with a MELSEC iQ-R series CPU module
When multiple programs are executed, the processing time (program switching time) becomes "Number of program files × 0.9 [us]". More Details >>
- No:22491
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:49
- Category: MELSEC iQ-R Series
-
You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
- Category: MELSEC iQ-R Series
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496
- Release Date:2018/09/03 17:28
- Update:2018/09/21 17:15
- Category: MELSEC iQ-R Series
-
Although it depends on interrupt factors, the overhead time before startup becomes 10.8 to 23.8 [us] and the time after startup becomes 6.5 to 17.4 [us]. More Details >>
- No:22499
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:14
- Category: MELSEC iQ-R Series
-
Difference between Q61P and Q64PN
There are differences in 5 VDC rated output current and in 5 VDC overcurrent protection.The difference in 5 VDC rated output current is as follows.- Q61P: 6 ... More Details >>
- No:22518
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Behavior of special relay in simulation
The constant scan initial value in the simulation function is 100ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set ... More Details >>
- No:22521
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:23
- Category: MELSEC-Q Series