Regarding communication data code for SLMP communication
It can not be set for each connection. More Details >>
- No:39312
- Release Date:2023/02/14 08:55
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the Certificate of non-applicability to export to other countries
For issuance of a certificate, please consult your local Mitsubishi representative. More Details >>
- No:22301
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:15
- Category: MELSEC iQ-F Series , Option , CPU Module , I/O Module , Engineering Software , Network/Communication , Motion/Positioning , High-Speed Counter , Analog
-
Regarding number of servo amplifiers that can be connected via PDO communication
The maximum number of servo amplifiers connected to the FX5-CCLGN-MS varies according to the number of axes. Example: When connecting a 3-axis servo amplifi... More Details >>
- No:44478
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding checking latch settings
You can find it in the Advanced Settings section of GX Works3. Use the following procedure to display the Device (High Speed) settings. From the GX Wor... More Details >>
- No:44364
- Release Date:2024/03/27 16:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the latch settings of data register
It is necessary to set the latch range from the following GX Works3 parameters: [Navigation Window] -> [CPU Parameters] -> [Device/Memory Settings] -&... More Details >>
- No:22329
- Release Date:2018/08/30 13:55
- Update:2024/11/11 13:49
- Category: CPU Module , Engineering Software
-
Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the maximum number of channels of high-speed counters
The FX5 CPU module's built-in high-speed counter can control up to 8CH. Up to 16CH can be controlled by adding 4 modules of FX5-16ET/E□-H (high-speed pulse ... More Details >>
- No:22311
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:34
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
Regarding the type of Ethernet connection cable
Ethernet standard-compatible cable, category 5 or higher (STP cable) can be used. *Straight cable can be used. When connecting directly to the computer, cr... More Details >>
- No:22295
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:23
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Yes, it is possible. Please consider functions such as Simple CPU communication or socket communication. More Details >>
- No:22294
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:00
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication