Regarding FX5-2HC/ES restrictions
The FX5-2HC/ES must be connected to the eighth module from the power supply module (CPU Module, expansion power supply module, built-in power supply I/O Modu... More Details >>
- No:44339
- Release Date:2024/03/20 13:25
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding nesting contacts displayed on bus by master control instructions
It is not possible. More Details >>
- No:39361
- Release Date:2023/02/15 13:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the number of FX5-4A-ADP connections
Up to 4 FX5-4A-ADPs can be connected to an FX5U/FX5UC/FX5S CPU module. To connect 3 or more FX5-4A-ADPs, the FX5-4A-ADP must have a serial number S/N: 224... More Details >>
- No:39348
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding how to back up FX5-4LC
Some buffer memory values are cleared when the power is turned off. Turn on the backup command before turning the power OFF. By turning the buffer memory ... More Details >>
- No:39347
- Release Date:2023/01/16 10:07
- Category: MELSEC iQ-F Series , Analog
-
Regarding converting FBD/LD Projects
It can't be converted. More Details >>
- No:39328
- Release Date:2023/02/14 09:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding device comment output to Data Logging Files
Device comments can not be output to data logging files. More Details >>
- No:39321
- Release Date:2023/02/14 09:00
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding bit specification index modification for word devices
Index modification cannot be done for bit specifications for Word device. More Details >>
- No:39299
- Release Date:2023/02/13 16:39
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding Extended File Register (ER) file names
File names can not be changed. It is fixed to EXFILER.ERD. More Details >>
- No:39296
- Release Date:2023/02/13 16:39
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding error 2440H on CPU module when using FX5-CCLGN-MS
When the power is turned on, the FX5-CCLGN-MS performs parameter check processing, and if an error occurs, the CPU module is also notified of the error. Ther... More Details >>
- No:39282
- Release Date:2023/01/12 16:49
- Category: MELSEC iQ-F Series , Network/Communication