FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-F Series ]
-
Regarding EtherNet/IP Communications
The built-in Ethernet port on the FX5 CPU module does not support EtherNet/IP communication. Use FX5-ENET/IP. More Details >>
- No:39319
- Release Date:2023/02/14 08:57
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the difference between digital output values and digital operation values
The digital output value is a digital value obtained by performing sampling processing or various average processing on the A/D converted digital value. Dig... More Details >>
- No:39307
- Release Date:2023/02/13 16:43
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding the number of terminating resistors of FX5-CCL-MS
Two terminating resistors are included. More Details >>
- No:39290
- Release Date:2023/01/12 16:52
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Open/Close Socket Communications
No need. More Details >>
- No:39288
- Release Date:2023/02/13 15:36
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Input filter adjustment when a high-speed counter or the interrupt function is used
When a coil of the high-speed counter or an interrupt pointer is programmed, the programmable controller system adjusts the filter constant of the correspond... More Details >>
- No:24867
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , High-Speed Counter
-
Regarding the expansion of modules after the bus conversion module
It is not possible to add an iQ-F series module after the bus conversion module. When adding an iQ-F series module, add it in the front stage of the bus conv... More Details >>
- No:45482
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding COM terminals of FX5-2HC/ES
Since the COM terminals is connected internally, there is no problem to use either one of them. More Details >>
- No:44874
- Release Date:2025/03/18 10:25
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding number of CH of CPU Module built-in Heating/Cooling PID control
The CPU Module's built-in Heating/Cooling PID control function supports up to 16 channels. The following firmware versions are required in order to use it. ... More Details >>
- No:44651
- Release Date:2025/03/18 10:22
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding TPDO and RPDO allocation
RWr is allocated to TPDO and RWw is allocated to RPDO. More Details >>
- No:44479
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding swapping upper and lower bytes of string data
You can use the SWAP (P) command to swap the upper and lower bytes of the specified device. More Details >>
- No:44361
- Release Date:2024/03/27 15:55
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
111-120 of Total 266