FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-F Series ]
-
Regarding checking the input/output data of the FX5-EIP
This can be checked by monitoring the corresponding buffer memory from the Register to Intelligent Function Module Monitor. From [Parameter] - [Module Infor... More Details >>
- No:45490
- Release Date:2025/05/08 09:08
- Update:2025/10/31 15:18
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the number of terminating resistors of FX5-CCL-MS
Two terminating resistors are included. More Details >>
- No:39290
- Release Date:2023/01/12 16:52
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding CC-Link IE Field Network Station Type
Local stations can obtain information about all device stations. Intelligent device stations can only obtain information about their own stations. FX5-CCLI... More Details >>
- No:39301
- Release Date:2023/01/12 16:52
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the difference between digital output values and digital operation values
The digital output value is a digital value obtained by performing sampling processing or various average processing on the A/D converted digital value. Dig... More Details >>
- No:39307
- Release Date:2023/02/13 16:43
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding the difference between the RS-485 expansion adapter and the extension board
The difference is the maximum transmission distance and the presence/absence of insulation (between the communication line and the CPU). ・Expansion Adapter ... More Details >>
- No:39315
- Release Date:2023/01/12 16:56
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding switching PID instructions for Auto-tuning
It's possible. More Details >>
- No:39320
- Release Date:2023/02/14 09:00
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding the line tracing function
It is not supported. More Details >>
- No:39323
- Release Date:2023/02/14 09:01
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the terminal arrangement of I/O module (extension connector type)
The connector's terminal arrangement is the smaller number on the left and larger number on the right. More Details >>
- No:39329
- Release Date:2023/01/12 16:57
- Category: MELSEC iQ-F Series , I/O Module
-
Regarding GX Works3 Module configuration diagram
It can't be configured. In the module configuration diagram of GX Works3, the configurations that can be created are those excluding FX5-CNV-IFC and FX3 Int... More Details >>
- No:39331
- Release Date:2023/02/14 09:08
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
131-140 of Total 266