Regarding MODBUS Device Allocation Settings
No need. The MODBUS device allocation settings are used when the MODBUS slave function is used. More Details >>
- No:40026
- Release Date:2023/08/24 14:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding FX5U/FX5UC CPU Module Built-in functions
The functions supported only by the FX5U/FX5UC CPU Modules are listed below. ・Predefined Protocol Support Function For Positioning function ・Optional batte... More Details >>
- No:40046
- Release Date:2023/08/24 16:14
- Update:2024/11/11 14:29
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding FX5-ENET, FX5-ENET/IP IP addresses
You cannot configure two IP addresses. More Details >>
- No:44356
- Release Date:2024/03/27 15:56
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding multiple connections for the MQTT communication function
The MQTT communication function of FX5-ENET does not allow multiple connections to be opened at the same time. The MQTT communication function has a maximum ... More Details >>
- No:44358
- Release Date:2024/03/27 16:02
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Control response parameter of built-in PID Control of CPU Module
The control response parameter can set the response to the target value (SV) of PID control as either "normal" or "fast". The difference is as follows. (1)W... More Details >>
- No:44653
- Release Date:2025/03/18 10:23
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding protocol mixing in Serial Communication
It is not possible to connect multiple devices with different communication speeds and parities. More Details >>
- No:45480
- Release Date:2025/11/12 13:54
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the processing specification of the basic operation instruction(LD).
The execution time of the basic opeartion instruction (LD) of the FX5U/FX5UC/FX5UJ CPU module is 34 ns. *For firmware Ver.1.100 or above, this specification ... More Details >>
- No:22287
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding error 2440H on CPU module when using FX5-CCLGN-MS
When the power is turned on, the FX5-CCLGN-MS performs parameter check processing, and if an error occurs, the CPU module is also notified of the error. Ther... More Details >>
- No:39282
- Release Date:2023/01/12 16:49
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Project verification
You can verify from GX Works3 Project - Verify with PLC. Manual GX Works3 Operating Manual More Details >>
- No:40028
- Release Date:2023/08/24 14:39
- Category: MELSEC iQ-F Series , Engineering Software