Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the differences between the FX5-2HC/ES and the conventional FX3U-2HC input formats
The FX5-2HC/ES supports differential line drivers (5 V) only. The FX3U-2HC supports open collectors (24 V/12 V/5 V) and differential line drivers (5 V). ... More Details >>
- No:44338
- Release Date:2024/03/26 09:02
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding Display Module Support
In the iQ-F series, there is no lineup of display modules. Consider usingweb server function. More Details >>
- No:40045
- Release Date:2023/08/24 15:53
- Update:2023/08/24 15:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding differences in simple CPU communication functions
There is no difference in functionality, only in the number of connections. More Details >>
- No:40039
- Release Date:2023/08/24 15:44
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding how to back up FX5-4LC
Some buffer memory values are cleared when the power is turned off. Turn on the backup command before turning the power OFF. By turning the buffer memory ... More Details >>
- No:39347
- Release Date:2023/01/16 10:07
- Category: MELSEC iQ-F Series , Analog
-
Regarding the possibility of adding an additional module to the FX5S CPU module
You cannot. The FX5S CPU module does not support the connection of an additional module (I/O module, Intelligent function module, FX5 safety extension modul... More Details >>
- No:39339
- Release Date:2023/02/14 17:28
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding performing Data Logging with Special Relays
It's possible. Using special relays, it is possible to perform data logging from a program. For details, see the manual below. MELSEC iQ-F FX5 User's Manu... More Details >>
- No:39327
- Release Date:2023/02/14 09:05
- Category: MELSEC iQ-F Series , CPU Module
-
Not supported. More Details >>
- No:39305
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module
-
The FX3 intelligent function modules cannot be selected from the Element selection window because it does not correspond to the parameter setting of GX Works... More Details >>
- No:22304
- Release Date:2018/08/30 13:55
- Update:2024/08/19 09:50
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding replacing FLT Instructions
For the iQ-F series, use the following instructions. For signed 16 bit integers, use the INT2FLT instruction. For unsigned 16 bit integers, use the UINT2FL... More Details >>
- No:45479
- Release Date:2025/11/12 13:54
- Category: MELSEC iQ-F Series , CPU Module