Regarding settings when the battery is installed
From the GX Works3 settings when the optional battery is installed, it must be set to Installed in the Optional Battery Settings. Use the following proc... More Details >>
- No:44363
- Release Date:2024/03/27 17:09
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding compatible version of CANopen communication function for PDO communication
It is necessary to use the following CPU module, FX5-CCLGN-MS, GX Works3 versions. FX5-CCLGN-MS・・・1.020 or later FX5U/FX5UC CPU module ・・・1.260 or later ... More Details >>
- No:44473
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding CC-Link IE TSN CANopen Communication function
The CANopen communication functions supported by the FX5-CCLGN-MS conform to the CiA402 CANopen profile, and can control devices that support the CiA402 devi... More Details >>
- No:44474
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
CC-Link IE field When a network such as Network Basic is interrupted, the CPU module does not stop and continues to run. When the CC-Link IE Field Network i... More Details >>
- No:44611
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding configuring of Data Logging
The CPU module logging feature is accessed from the CPU module logging configuration tool. If the tool is installed, launch it from GX Works3 Tools > Logg... More Details >>
- No:44613
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the data link program of FX5-CCL-MS
Since the FX5-CCL-MS has a link refresh setting, there is no need for a program to read and write data to each station. More Details >>
- No:44614
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding COM terminals of FX5-2HC/ES
Since the COM terminals is connected internally, there is no problem to use either one of them. More Details >>
- No:44874
- Release Date:2025/03/18 10:25
- Category: MELSEC iQ-F Series , High-Speed Counter
-
The FX5 CPU module does not support UDP broadcast communication. More Details >>
- No:22291
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the type of Ethernet connection cable
Ethernet standard-compatible cable, category 5 or higher (STP cable) can be used. *Straight cable can be used. When connecting directly to the computer, cr... More Details >>
- No:22295
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:23
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the range of latch devices
The latch range can be set arbitrarily by the customer. The settings can be found in the memory/device settings of CPU parameters. To back up the link regist... More Details >>
- No:22297
- Release Date:2018/08/30 13:55
- Category: MELSEC iQ-F Series , CPU Module