Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding updating the FX5U/FX5UC CPU module to firmware version “1.100 ” or later
To update to firmware version “1.100 ” or higher, you need a product with serial number (S/N) or higher listed below. ・FX5UC-32MT/DS-TS and FX5UC-32MT/DSS-T... More Details >>
- No:44623
- Release Date:2024/11/28 16:14
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding how to compare multiple word devices
It is possible to compare multiple word devices using the BKCMP_□ instruction. *where □ is the comparison symbol. Example:To compare 10 stores from D0 to D... More Details >>
- No:44616
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding how to generate a false error
There is no function to generate a false error. For example, if operand (s2): divisor is set to "0" in the division command and the command is executed, err... More Details >>
- No:44610
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the login screen for the Web Server Function
There is no setting or method to disable the login screen for the web server function. More Details >>
- No:44357
- Release Date:2024/03/27 15:52
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding FX5-ENET, FX5-ENET/IP IP addresses
You cannot configure two IP addresses. More Details >>
- No:44356
- Release Date:2024/03/27 15:56
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding dedicated instruction for JOG operation
There is no dedicated instruction to drive JOG. Use PLSV (variable speed operation) when operating JOG. More Details >>
- No:44355
- Release Date:2024/03/27 15:50
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding Bus Conversion Module Differences
The FX5-CNV-BUS is an additional cable type. ・Used when the FX5-CNV-BUS previous module is an expansion cable type module. The FX5-CNV-BUSC is an a... More Details >>
- No:44353
- Release Date:2024/03/27 15:49
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding differences between Analog Module and Analog Adapters
FX5-4AD and FX5-4DA are intelligent function Modules. ・Connect to the right side of the CPU Module. ・Control via buffer memory (BFM). ・It also supports ... More Details >>
- No:44347
- Release Date:2024/03/27 15:21
- Category: MELSEC iQ-F Series , Analog