FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-F Series ]
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regarding number of input/output points when adding safety extension module
It will. It is treated the same as an intelligent module, so it occupies 8 I/O points. The safety input expansion module FX5-SF-8DI4 does not occupy the numb... More Details >>
- No:39314
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , CPU Module , Safety Control
-
Regarding how to generate a false error
There is no function to generate a false error. For example, if operand (s2): divisor is set to "0" in the division command and the command is executed, err... More Details >>
- No:44610
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding I/O assignment on the module configuration diagram of GX Works3
While the module configuration window is being displayed, the I/O assignment can be checked by selecting the following options from the menu bar: [Edit]→[X... More Details >>
- No:22307
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:25
- Category: CPU Module , I/O Module , Engineering Software
-
Regarding GX Works3 Module configuration diagram
It can't be configured. In the module configuration diagram of GX Works3, the configurations that can be created are those excluding FX5-CNV-IFC and FX3 Int... More Details >>
- No:39331
- Release Date:2023/02/14 09:08
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the login screen for the Web Server Function
There is no setting or method to disable the login screen for the web server function. More Details >>
- No:44357
- Release Date:2024/03/27 15:52
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
From the following menu of GX Works3: [Diagnostics]→[Module Diagnostics(CPU Diagnostics)] the event history function can be found. The event history can dis... More Details >>
- No:22305
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding differences between Analog Module and Analog Adapters
FX5-4AD and FX5-4DA are intelligent function Modules. ・Connect to the right side of the CPU Module. ・Control via buffer memory (BFM). ・It also supports ... More Details >>
- No:44347
- Release Date:2024/03/27 15:21
- Category: MELSEC iQ-F Series , Analog
-
Regarding swapping upper and lower bytes of string data
You can use the SWAP (P) command to swap the upper and lower bytes of the specified device. More Details >>
- No:44361
- Release Date:2024/03/27 15:55
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding configuring of Data Logging
The CPU module logging feature is accessed from the CPU module logging configuration tool. If the tool is installed, launch it from GX Works3 Tools > Logg... More Details >>
- No:44613
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software