Yes, it is possible. Please consider functions such as Simple CPU communication or socket communication. More Details >>
- No:22294
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:00
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
Regarding CC-Link IE Field Network Basic Refresh Settings
You can't. Device allocation for refresh settings is sequential only. More Details >>
- No:39306
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the differences between CC-Link IE TSN and CC-Link IE Field Networks
(1)Whether or not networks can be mixed on the same trunk line is different. CC-Link IE TSN allows network mixing on the same trunk line. When using a CC-Li... More Details >>
- No:39359
- Release Date:2023/01/12 17:10
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding maximum number of connections for the simple CPU communication function
The maximum number of connections for the simple CPU communication function of FX5 CPU module is 16 for FX5U/FX5UC CPU module and 8 for FX5UJ/FX5S CPU module... More Details >>
- No:40032
- Release Date:2023/08/24 15:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the system configuration of FX5-CCL-MS with FX5 CPU module
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>
- No:22318
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:50
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding setting the FX5 CPU Module that does not support the simple CPU communication function
When connecting 2 FX5 CPU Modules (firmware version 1.110 or later) that support the Simple CPU communication function and 2 FX5 CPU Modules (firmware vers... More Details >>
- No:44329
- Release Date:2024/03/20 13:35
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the maximum number of controllable axes of the bulit-in positioning function
Up to 4 axes can be controlled. Please use a transistor output type CPU module. (By adding a high speed pulse input/output module, maximum 12 axes (CPU bui... More Details >>
- No:22300
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:52
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding MODBUS/TCP communication of the built-in Ethernet port
When used as a master station, communication with a slave station can be performed using the simple CPU communication or the predefined protocol support func... More Details >>
- No:22302
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:52
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication