Regarding the clean session function of MQTT communication function
This function allows you to select the operation to be performed when the FX5-ENET(MQTT client) reconnects to the MQTT broker after communication has been ... More Details >>
- No:40054
- Release Date:2023/08/25 09:02
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding FX5S CPU module Terminal Block Removal
You can't put it on or take it off. The terminal block of the FX5S CPU module is a non-removable terminal block. More Details >>
- No:39334
- Release Date:2023/02/14 09:10
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding EtherNet/IP communication function for FX5-EIP
The following EtherNet/IP communication functions are supported by the FX5-EIP. ・Cyclic communication function ⇒Class1 instance communication/tag communicat... More Details >>
- No:45483
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding COM terminals of FX5-2HC/ES
Since the COM terminals is connected internally, there is no problem to use either one of them. More Details >>
- No:44874
- Release Date:2025/03/18 10:25
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding whether ladder monitoring is enabled by the Web server function
You cannot use the ladder monitor with the Web server function. With the Web server function, it is possible to monitor the device value, test the device (w... More Details >>
- No:44873
- Release Date:2025/03/18 10:23
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the data link program of FX5-CCL-MS
Since the FX5-CCL-MS has a link refresh setting, there is no need for a program to read and write data to each station. More Details >>
- No:44614
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding restrictions on the external input/output forced ON/OFF function
The following restrictions apply to the external input/output forced ON/OFF function. ・Since RUN contact setting is RUN/STOP by external signal, forced ON/O... More Details >>
- No:44332
- Release Date:2024/03/20 12:58
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding terminal block reuse
Terminal blocks can not be reused. Please rewire it. More Details >>
- No:39365
- Release Date:2023/02/15 13:06
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding device comment output to Data Logging Files
Device comments can not be output to data logging files. More Details >>