Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding bit specification index modification for word devices
Index modification cannot be done for bit specifications for Word device. More Details >>
- No:39299
- Release Date:2023/02/13 16:39
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the effect of battery voltage drop on logging function
Since the battery retains clock data even after power failure, the time of logging data may change. More Details >>
- No:39310
- Release Date:2023/01/12 16:53
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding communication data code for SLMP communication
It can not be set for each connection. More Details >>
- No:39312
- Release Date:2023/02/14 08:55
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the COM terminal of the multiple input module
Yes, it's connected internally. More Details >>
- No:39318
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , Analog
-
Regarding performing Data Logging with Special Relays
It's possible. Using special relays, it is possible to perform data logging from a program. For details, see the manual below. MELSEC iQ-F FX5 User's Manu... More Details >>
- No:39327
- Release Date:2023/02/14 09:05
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the possibility of adding an additional module to the FX5S CPU module
You cannot. The FX5S CPU module does not support the connection of an additional module (I/O module, Intelligent function module, FX5 safety extension modul... More Details >>
- No:39339
- Release Date:2023/02/14 17:28
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding clearing the maximum and minimum scan times
It can be cleared with the scan time clear function. You can clear maximum and minimum scan time with GX Works3 Ver. 1.085 P or later or by special relays. More Details >>
- No:39342
- Release Date:2023/02/15 10:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding how to back up FX5-4LC
Some buffer memory values are cleared when the power is turned off. Turn on the backup command before turning the power OFF. By turning the buffer memory ... More Details >>
- No:39347
- Release Date:2023/01/16 10:07
- Category: MELSEC iQ-F Series , Analog
-
Regarding reading Sample Comments for Expansion Adapters
You cannot. The expansion adapters does not support reading sample comments. More Details >>
- No:39352
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
21-30 of Total 253