Regarding the digital output of the built-in analog function
It is possible by setting the scaling function or shift function from the parameter settings. More Details >>
- No:22315
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:46
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Regardng compatability with other product series
Although the connection with FX2N series I/O modules, FX2 series intelligent function modules, and FX3 series special adater is not possible, FX3 series inte... More Details >>
- No:22309
- Release Date:2018/08/30 13:55
- Update:2022/12/22 09:46
- Category: MELSEC iQ-F Series , CPU Module , I/O Module
-
Regarding Instruction description help in GX Works3
You can open the descriptions for each instruction by moving the cursor to the target instruction and pressing F1. You can also hover the cursor over it and ... More Details >>
- No:39366
- Release Date:2023/02/15 13:06
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding comparison of Strings
Use the string comparison instructions LD$□, AND$□, OR$□. □contains =, <>, >, < =, <, > =. More Details >>
- No:39355
- Release Date:2023/02/15 13:03
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the input circuit wiring of the FX5 CPU module
Yes. There is no problem using an external power supply for the input circuit of the FX5 CPU module. More Details >>
- No:39317
- Release Date:2023/02/14 08:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
Regarding number of occupied I/O points of intelligent function module
The number of occupied input/output points per module is 8. (Excluding some models) Occupied I/O points: Since actual occupied I/O points cannot be assigned... More Details >>
- No:44612
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding how to check the date of manufacture
The date of manufacture of a product can be confirmed by the following methods. ① Name plate verification There is a name plate on the right side of the pr... More Details >>
- No:44878
- Release Date:2025/03/18 11:11
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the procedure for functions set in GX Works3
This is possible with the Guidance flow function. On GX Works3, you can view the setting procedure for the function you want to use. *It is supported by GX ... More Details >>
- No:39341
- Release Date:2023/02/14 17:29
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software