Regarding use of the FTP Server Auto Transfer Function with Other Functions
Be careful when using the FTP server auto transfer function in combination with the following functions. ・FTP client (FTPPUT instruction) The function exe... More Details >>
- No:44336
- Release Date:2024/03/20 13:28
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding forced ON/OFF function for external input/output
The "Forced ON/OFF function for external input/output" that forces X/Y devices to turn on/off from GX Works3 is supported with the following firmware version... More Details >>
- No:44330
- Release Date:2024/03/20 12:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding double-precision real numbers
The FX5 CPU unit does not handle double-precision real numbers. Only single-precision real numbers can be handled. More Details >>
- No:40033
- Release Date:2023/08/24 15:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding maximum number of connections for the simple CPU communication function
The maximum number of connections for the simple CPU communication function of FX5 CPU module is 16 for FX5U/FX5UC CPU module and 8 for FX5UJ/FX5S CPU module... More Details >>
- No:40032
- Release Date:2023/08/24 15:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding parameter setting for FX5-CCL-MS
It is possible to set the basic/application settings in a program by selecting the parameter setting method to "Program." Even if set by "program" is select... More Details >>
- No:39367
- Release Date:2023/01/12 17:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding differences between 8 bit and 16 bit modes for non-protocol communication
In 8-bit mode, the upper 8 bits of transmitted and received data are ignored and only the lower 8 bits are valid data. In 16 bit mode, send/receive data i... More Details >>
- No:39363
- Release Date:2023/02/15 13:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding nesting contacts displayed on bus by master control instructions
It is not possible. More Details >>
- No:39361
- Release Date:2023/02/15 13:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding handling multiple executions of ADPRW Instructions
When multiple ADPRW instructions are simultaneously executed, communication by the ADPRW command that was executed earlier is completed and communication by ... More Details >>
- No:39354
- Release Date:2023/02/15 10:17
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding input of Differential Driver Output Type
It does not. The built-in high-speed counter of the FX5U/FX5UC CPU module does not support DC5V input. DC5V input can be achieved by adding BUS conversion mo... More Details >>
- No:39350
- Release Date:2023/01/12 17:09
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding how to back up FX5-4LC
Some buffer memory values are cleared when the power is turned off. Turn on the backup command before turning the power OFF. By turning the buffer memory ... More Details >>
- No:39347
- Release Date:2023/01/16 10:07
- Category: MELSEC iQ-F Series , Analog