FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-F Series ]
-
Regarding FX5U/FX5UC CPU Module Built-in functions
The functions supported only by the FX5U/FX5UC CPU Modules are listed below. ・Predefined Protocol Support Function For Positioning function ・Optional batte... More Details >>
- No:40046
- Release Date:2023/08/24 16:14
- Update:2024/11/11 14:29
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding enclosed power cable for input module and input/output module for extension connector type
The FX2NC-100BPCB is included with the following products. CPU Modules: FX5UC-32 MT/D, FX5UC-64 MT/D, FX5UC-96 MT/D More Details >>
- No:40047
- Release Date:2023/08/24 16:30
- Update:2024/05/09 09:59
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding setting up encrypted communication (TLS) for FX5-ENET
In GX Works3, set the FX5-ENET module parameters from Basic Settings - External Device Configuration Settings. In the "Ethernet Configuration" screen, selec... More Details >>
- No:40050
- Release Date:2023/08/25 08:48
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the Number of Sending Addresses for Email function
The FX5-ENET module parameter of GX Works3 can send up to 10 messages and the module FB can send up to 256 characters at a time. By entering multiple email ... More Details >>
- No:40052
- Release Date:2023/08/25 10:23
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the clean session function of MQTT communication function
This function allows you to select the operation to be performed when the FX5-ENET(MQTT client) reconnects to the MQTT broker after communication has been ... More Details >>
- No:40054
- Release Date:2023/08/25 09:02
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding specifications of the forced ON/OFF function for external input/output
The following points are different for the iQ-F series. ・All output disabled flag (SM8034) When SM8034 is ON, the all output disabled flag is given priorit... More Details >>
- No:44331
- Release Date:2024/03/20 12:54
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the differences between the FX5-2HC/ES and the conventional FX3U-2HC input formats
The FX5-2HC/ES supports differential line drivers (5 V) only. The FX3U-2HC supports open collectors (24 V/12 V/5 V) and differential line drivers (5 V). ... More Details >>
- No:44338
- Release Date:2024/03/26 09:02
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding FX5-2HC/ES restrictions
The FX5-2HC/ES must be connected to the eighth module from the power supply module (CPU Module, expansion power supply module, built-in power supply I/O Modu... More Details >>
- No:44339
- Release Date:2024/03/20 13:25
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding write speed during RUN
CC-Link IE field Network Basic communication interval can be set with special relay and special register. During debugging, adjust the communication interv... More Details >>
- No:44342
- Release Date:2024/03/20 13:39
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding using the connector of the CPU Module
The input/output cables used in the FX3GC and FX3UC basic units can be diverted to the FX5UC CPU Module (connector type). More Details >>
- No:44350
- Release Date:2024/03/27 15:44
- Category: MELSEC iQ-F Series , CPU Module