Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
- Category: MELSEC iQ-F Series , Network/Communication
-
The FX5 CPU module does not support CAN communication. More Details >>
- No:39286
- Release Date:2023/02/13 15:36
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the number of terminating resistors of FX5-CCL-MS
Two terminating resistors are included. More Details >>
- No:39290
- Release Date:2023/01/12 16:52
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding CC-Link IE Field Network Station Type
Local stations can obtain information about all device stations. Intelligent device stations can only obtain information about their own stations. FX5-CCLI... More Details >>
- No:39301
- Release Date:2023/01/12 16:52
- Category: MELSEC iQ-F Series , Network/Communication
-
Not supported. More Details >>
- No:39305
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the input circuit wiring of the FX5 CPU module
Yes. There is no problem using an external power supply for the input circuit of the FX5 CPU module. More Details >>
- No:39317
- Release Date:2023/02/14 08:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding FX5S CPU module Terminal Block Removal
You can't put it on or take it off. The terminal block of the FX5S CPU module is a non-removable terminal block. More Details >>
- No:39334
- Release Date:2023/02/14 09:10
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the FX5S CPU Module Line-up
The line-up of input and output points of the FX5S CPU module is as follows. ・30 points (Input: 16 points, Output: 14 points) ・40 points (Input: 24 points,... More Details >>
- No:39340
- Release Date:2023/02/14 17:28
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Instruction processing time when the program capacity: 128 K steps are set
LD instruction: 0.35 μs, MOV instruction: 0.779 μs. For other instructions, see the manual below. MELSEC iQ-F FX5 Programming Manual (Instructions, Standa... More Details >>
- No:39362
- Release Date:2023/01/12 17:12
- Category: MELSEC iQ-F Series , CPU Module