FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-F Series ]
-
Regarding TPDO and RPDO allocation
RWr is allocated to TPDO and RWw is allocated to RPDO. More Details >>
- No:44479
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the expansion of modules after the bus conversion module
It is not possible to add an iQ-F series module after the bus conversion module. When adding an iQ-F series module, add it in the front stage of the bus conv... More Details >>
- No:45482
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding number of servo amplifiers that can be connected via PDO communication
The maximum number of servo amplifiers connected to the FX5-CCLGN-MS varies according to the number of axes. Example: When connecting a 3-axis servo amplifi... More Details >>
- No:44478
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding support for the FX5-EIP Auto refresh function
The Auto refresh function is supported. More Details >>
- No:45488
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Data Collection for Device Comments
It is not possible to collect device comments. More Details >>
- No:40030
- Release Date:2023/08/24 14:40
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the switching Hubs that can be used for CC-Link IE TSN
The CC-Link IE TSN has a CC-Link IE TSN Class B/A, and the available switching HUBs are also specified by supported standards, synchronization accuracy, etc.... More Details >>
- No:39284
- Release Date:2023/01/12 16:50
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding replacement from 128 point type of FX3U
The FX5U CPU module has a lineup of up to 80 point. The following configuration is recommended when replacing the FX3U-128MR/ES. Recommended alternative (1... More Details >>
- No:44617
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the simultaneous use of Simple CPU Communication and FX5-CCLGN-MS MELSOFT Connection
Can be used simultaneously. More Details >>
- No:39285
- Release Date:2023/01/12 16:50
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the number of expansion adapters and expansion board connections for FX5S CPU module
Up to 6 devices can be connected. Extension adapters/boards (Max. 2 units) + analog extension adapters (Max. 4 units). *Using an SD memory card module ... More Details >>
- No:39336
- Release Date:2023/02/14 17:13
- Category: MELSEC iQ-F Series , CPU Module
1-10 of Total 266