Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the FX5S CPU Module Line-up
The line-up of input and output points of the FX5S CPU module is as follows. ・30 points (Input: 16 points, Output: 14 points) ・40 points (Input: 24 points,... More Details >>
- No:39340
- Release Date:2023/02/14 17:28
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Display Module Support
In the iQ-F series, there is no lineup of display modules. Consider usingweb server function. More Details >>
- No:40045
- Release Date:2023/08/24 15:53
- Update:2023/08/24 15:56
- Category: MELSEC iQ-F Series , CPU Module
-
Not supported. More Details >>
- No:39305
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the COM terminal of the multiple input module
Yes, it's connected internally. More Details >>
- No:39318
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , Analog
-
Regarding Gray code conversion
There is. Please use the GBIN instruction. More Details >>
- No:39322
- Release Date:2023/02/14 09:02
- Category: MELSEC iQ-F Series , CPU Module
-
Use the POW (Single Precision Real Power Operation) instruction. More Details >>
- No:40029
- Release Date:2023/08/24 14:38
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding Free Mail Service with Email Function
Free mail services that have been verified to work with the email function are Gmail, Yahoo! mail, and iCloud email.(As of July 2025) Use the encryption fun... More Details >>
- No:40058
- Release Date:2023/08/25 10:22
- Update:2025/11/11 14:31
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding COM terminals of FX5-2HC/ES
Since the COM terminals is connected internally, there is no problem to use either one of them. More Details >>
- No:44874
- Release Date:2025/03/18 10:25
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding FX5S CPU module Terminal Block Removal
You can't put it on or take it off. The terminal block of the FX5S CPU module is a non-removable terminal block. More Details >>
- No:39334
- Release Date:2023/02/14 09:10
- Category: MELSEC iQ-F Series , CPU Module
1-10 of Total 266