Regarding the type of battery which c...
FX3U-32BL can be used. The battery is not included with the CPU modu... More Details >>
It is used for switching between Sink/Source input. For sink input wiring, connect with "24V" terminal and short-circuit the "0V" and "input X***". For sourc... More Details >>
Regarding the processing specificatio...
The execution time of the basic opeartion instruction(LD) is 0.034[μs]. *For firmware Ver.1.100 or above, this specification applies to 64K step mode. More Details >>
Regarding the compatible programming ...
GX Developer/GX Works2 cannot be used. MELSEC iQ-F series only supports GX Works3. More Details >>
Regarding the necessity of using a ba...
Device back up is available without using a battery. However, to back up link register (W) and file register (R) devices, a battery is required. More Details >>
Regarding the range of latch devices
The latch range can be set arbitrarily by the customer. The settings can be found in the memory/device settings of CPU parameters. To back up the link regist... More Details >>
Regarding address change of positioni...
It can be changed. For example, with the positioning instruction, a word device can be assigned to the operand which specifies the positioning address and th... More Details >>
Regarding speed change of positioning...
It can be changed. For details, please refer to MELSEC iQ-F FX5 User's Manual (Positioning Control - CPU module built-in, high speed pulse input/output modul... More Details >>
Regarding the digital output of the b...
It is possible by setting the scaling function or shift function from the parameter settings. More Details >>
Regarding the system configuration of...
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>