Regarding how to check the date of manufacture
The date of manufacture of a product can be confirmed by the following methods. ① Name plate verification There is a name plate on the right side of the pr... More Details >>
- No:44878
- Release Date:2025/03/18 11:11
-
Regarding number of CC-Link IE field network Basic connections
When the FX5 CPU Module is used as the master station, the maximum number of devices connected to 1 network is 16. The following firmware versions are requi... More Details >>
- No:44652
- Release Date:2025/03/18 10:22
-
Regarding CC-Link IE field network support of FX5 CPU module built-in Ethernet
The built-in Ethernet on the FX5 CPU module does not support CC-Link IE field networks. If you use a CC-Link IE field network, add an FX5-CCLIEF. *The FX5-... More Details >>
- No:44877
- Release Date:2025/03/18 10:30
-
Regarding scan time adjustment for replacing the FX3 Series
You can adjust by setting the constant scan in iQ-F series. Setting procedure: Navigation window > [Parameter] > [Module model name] > [CPU Paramet... More Details >>
- No:44866
- Release Date:2025/03/18 10:24
-
Regarding whether ladder monitoring is enabled by the Web server function
You cannot use the ladder monitor with the Web server function. With the Web server function, it is possible to monitor the device value, test the device (w... More Details >>
- No:44873
- Release Date:2025/03/18 10:23
-
Regarding Recommended Substitute Models for FX3G-CNV-ADP
The FX5 CPU modules allows you to add an expansion adapter without using a connector conversion adapter. Therefore, there is no Recommended Substitute Models... More Details >>
- No:44875
- Release Date:2025/03/18 10:27
-
Regarding How to release Online Program Change
In GX Works3, [Tools] - [Options] - [Conversion] - [Online Program Change], set "Execute Online Program Change in Converting" to "No." More Details >>
- No:44876
- Release Date:2025/03/18 10:26
-
Regarding reuse of GOT connector cable when replacing with FX5 CPU module
The connection cable is GT01-C30R4-8P. The FX5U CPU module does not have an RS422 port, so you will need to add an FX5-422-BD-GOT. More Details >>
- No:44615
- Release Date:2024/11/28 16:13
-
Regarding using the connector of the CPU Module
The input/output cables used in the FX3GC and FX3UC basic units can be diverted to the FX5UC CPU Module (connector type). More Details >>
- No:44350
- Release Date:2024/03/27 15:44
-
Regarding replacement from 128 point type of FX3U
The FX5U CPU module has a lineup of up to 80 point. The following configuration is recommended when replacing the FX3U-128MR/ES. Recommended alternative (1... More Details >>
- No:44617
- Release Date:2024/11/28 16:13