Regarding replacement from 128 point type of FX3U
The FX5U CPU module has a lineup of up to 80 point. The following configuration is recommended when replacing the FX3U-128MR/ES. Recommended alternative (1... More Details >>
- No:44617
- Release Date:2024/11/28 16:13
-
Regarding how to generate a false error
There is no function to generate a false error. For example, if operand (s2): divisor is set to "0" in the division command and the command is executed, err... More Details >>
- No:44610
- Release Date:2024/11/28 16:11
-
CC-Link IE field When a network such as Network Basic is interrupted, the CPU module does not stop and continues to run. When the CC-Link IE Field Network i... More Details >>
- No:44611
- Release Date:2024/11/28 16:11
-
Regarding number of occupied I/O points of intelligent function module
The number of occupied input/output points per module is 8. (Excluding some models) Occupied I/O points: Since actual occupied I/O points cannot be assigned... More Details >>
- No:44612
- Release Date:2024/11/28 16:12
-
Regarding reuse of GOT connector cable when replacing with FX5 CPU module
The connection cable is GT01-C30R4-8P. The FX5U CPU module does not have an RS422 port, so you will need to add an FX5-422-BD-GOT. More Details >>
- No:44615
- Release Date:2024/11/28 16:13
-
Regarding communication data code for SLMP communication
It can not be set for each connection. More Details >>
- No:39312
- Release Date:2023/02/14 08:55
-
Regarding how to compare multiple word devices
It is possible to compare multiple word devices using the BKCMP_□ instruction. *where □ is the comparison symbol. Example:To compare 10 stores from D0 to D... More Details >>
- No:44616
- Release Date:2024/11/28 16:13
-
Regarding updating the FX5U/FX5UC CPU module to firmware version “1.100 ” or later
To update to firmware version “1.100 ” or higher, you need a product with serial number (S/N) or higher listed below. ・FX5UC-32MT/DS-TS and FX5UC-32MT/DSS-T... More Details >>
- No:44623
- Release Date:2024/11/28 16:14
-
Regarding using the 2nsec Clock Timer
The value of n can be set in SD414, and the range is from K1 to K32767. (Default value: K30) If n=K1, it is a 2-second clock timer with 1 second ON/1 second... More Details >>
- No:40019
- Release Date:2023/08/24 14:29
-
From the [Module] tab ⇒ [Module FB] in the [Element Selection] window of GX Works3, drag and drop the Module FB you want to use to the program editor. More Details >>
- No:44606
- Release Date:2024/11/28 16:11