- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding the expansion of modules after the bus conversion module
It is not possible to add an iQ-F series module after the bus conversion module. When adding an iQ-F series module, add it in the front stage of the bus conv... More Details >>
- No:45482
- Release Date:2025/11/12 13:55
-
Regarding whether ladder monitoring is enabled by the Web server function
You cannot use the ladder monitor with the Web server function. With the Web server function, it is possible to monitor the device value, test the device (w... More Details >>
- No:44873
- Release Date:2025/03/18 10:23
-
Regarding Extended File Register (ER) file names
File names can not be changed. It is fixed to EXFILER.ERD. More Details >>
- No:39296
- Release Date:2023/02/13 16:39
-
Regarding using the 2nsec Clock Timer
The value of n can be set in SD414, and the range is from K1 to K32767. (Default value: K30) If n=K1, it is a 2-second clock timer with 1 second ON/1 second... More Details >>
- No:40019
- Release Date:2023/08/24 14:29
-
Regarding enclosed power cable for input module and input/output module for extension connector type
The FX2NC-100BPCB is included with the following products. CPU Modules: FX5UC-32 MT/D, FX5UC-64 MT/D, FX5UC-96 MT/D More Details >>
- No:40047
- Release Date:2023/08/24 16:30
- Update:2024/05/09 09:59
-
Regarding USB Cable Recommendations
A recommended USB cable is provided. ・MR-J3USBCBL3M(3 m) ・GT09-C30USB-5P(3 m) (manufactured by Mitsubishi Electric System Service Co., Ltd.) More Details >>
- No:40040
- Release Date:2023/08/24 15:45
-
Regarding specifications of the forced ON/OFF function for external input/output
The following points are different for the iQ-F series. ・All output disabled flag (SM8034) When SM8034 is ON, the all output disabled flag is given priorit... More Details >>
- No:44331
- Release Date:2024/03/20 12:54
-
Regarding number of occupied I/O points of intelligent function module
The number of occupied input/output points per module is 8. (Excluding some models) Occupied I/O points: Since actual occupied I/O points cannot be assigned... More Details >>
- No:44612
- Release Date:2024/11/28 16:12
-
Regarding maximum number of years of clock data that can be handled
The maximum number of years of the clock function is 2079 years. If it exceeds the maximum number of years, it will be fixed at 23:59:59 on December 31, 207... More Details >>
- No:45478
- Release Date:2025/11/12 13:54
-
Regarding protocol mixing in Serial Communication
It is not possible to connect multiple devices with different communication speeds and parities. More Details >>
- No:45480
- Release Date:2025/11/12 13:54
1-10 of Total 185