Regarding how to generate a false error
There is no function to generate a false error. For example, if operand (s2): divisor is set to "0" in the division command and the command is executed, err... More Details >>
- No:44610
- Release Date:2024/11/28 16:11
-
Regarding protocol mixing in Serial Communication
It is not possible to connect multiple devices with different communication speeds and parities. More Details >>
- No:45480
- Release Date:2025/11/12 13:54
-
Regarding the number of available channels of the built-in high speeed counters.
The high-speed counter supports 1-phase 1-input, 1-phase 2-input, 2-phase 2-input. The built-in counter in the CPU module can input up to 8ch. However,... More Details >>
- No:22310
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:42
-
Regarding the digital output of the built-in analog function
It is possible by setting the scaling function or shift function from the parameter settings. More Details >>
- No:22315
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:46
-
Regarding communication data code for SLMP communication
It can not be set for each connection. More Details >>
- No:39312
- Release Date:2023/02/14 08:55
-
Regarding the communication execution status output device for ADPRW instructions
It does not turn OFF automatically. Use the RST command in the program to turn it OFF. More Details >>
- No:39349
- Release Date:2023/02/15 10:07
-
Regarding the difference of current address (user unit, pulse unit)
The difference between the current address (user unit) and the current address (pulse unit) is as follows: The current address (user unit) becomes the unit ... More Details >>
- No:39357
- Release Date:2023/02/15 13:05
-
Regarding differences between 8 bit and 16 bit modes for non-protocol communication
In 8-bit mode, the upper 8 bits of transmitted and received data are ignored and only the lower 8 bits are valid data. In 16 bit mode, send/receive data i... More Details >>
- No:39363
- Release Date:2023/02/15 13:04
-
Regarding analog volume support
With the FX5 CPU module , there is no CPU module or option that supports analog volumes. More Details >>
- No:40044
- Release Date:2023/08/24 16:13
-
Reagrding specifying an FTP client domain
The iQ-F series does not support domain specification, so specify the IP address. More Details >>
- No:44359
- Release Date:2024/03/27 15:58