- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding SFC Language Support
The FX5 CPU module supports SFC language with the following firmware versions. ・FX5U/FX5UC Ver. 1.220 or later ・FX5UJ Ver. 1.050 or later ・FX5S Ver. 1.010... More Details >>
- No:40043
- Release Date:2023/08/24 15:47
-
Regarding automatic transfer of Data Logging Files
Data logging file transfer (FTP server auto transfer) is supported with the following firmware versions. ・FX5U/FX5UC CPU Module Ver. 1.300 or later ・FX5U... More Details >>
- No:44334
- Release Date:2024/03/20 13:30
-
Regarding settings when the battery is installed
From the GX Works3 settings when the optional battery is installed, it must be set to Installed in the Optional Battery Settings. Use the following proc... More Details >>
- No:44363
- Release Date:2024/03/27 17:09
-
Regarding printing of cross-references
If cross-references are displayed on GX Works3, you can print them. More Details >>
- No:44619
- Release Date:2024/11/28 16:10
-
Regarding speed change of positioning operation.
It can be changed. For details, please refer to MELSEC iQ-F FX5 User's Manual (Positioning Control - CPU module built-in, high speed pulse input/output modu... More Details >>
- No:22299
- Release Date:2018/08/30 13:55
- Update:2023/02/14 09:52
-
Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
-
Regarding firmware updates for newly purchased CPU modules
You can still update the firmware. More Details >>
- No:39300
- Release Date:2023/02/13 16:40
-
Regarding the difference between digital output values and digital operation values
The digital output value is a digital value obtained by performing sampling processing or various average processing on the A/D converted digital value. Dig... More Details >>
- No:39307
- Release Date:2023/02/13 16:43
-
Regarding simultaneous access to Web Server function
The Web server function allows you to log in from up to four devices at the same time. You can't log in from the fifth machine. More Details >>
- No:39330
- Release Date:2023/02/14 09:06
-
Regarding connection through a MODBUS/TCP Gateway
Communication is possible with simple CPU communication function of FX5CPU, FX5-ENET, FX5-ENET/IP modules. ※FX5U and FX5UC CPU modules with firmware version... More Details >>
- No:39343
- Release Date:2023/01/12 17:05
- Update:2023/06/23 11:13