Regarding nesting contacts displayed on bus by master control instructions
It is not possible. More Details >>
- No:39361
- Release Date:2023/02/15 13:04
-
Regarding converting FBD/LD Projects
It can't be converted. More Details >>
- No:39328
- Release Date:2023/02/14 09:05
-
Regarding device comment output to Data Logging Files
Device comments can not be output to data logging files. More Details >>
- No:39321
- Release Date:2023/02/14 09:00
-
Regarding number of input/output points when adding safety extension module
It will. It is treated the same as an intelligent module, so it occupies 8 I/O points. The safety input expansion module FX5-SF-8DI4 does not occupy the numb... More Details >>
- No:39314
- Release Date:2023/01/12 16:54
-
Regarding the HOLD/CLEAR function of the built-in analog output
This function allows you to select the digital value to perform D/A conversion from the following three patterns depending on the operating status of the CPU... More Details >>
- No:39289
- Release Date:2023/01/12 16:51
-
Regarding the number of available channels of the built-in high speeed counters.
The high-speed counter supports 1-phase 1-input, 1-phase 2-input, 2-phase 2-input. The built-in counter in the CPU module can input up to 8ch. However,... More Details >>
- No:22310
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:42
-
Regarding the type of battery which can be used with the CPU module.
FX3U-32BL can be used. The battery is not included with the CPU modu... More Details >>
- No:22285
- Release Date:2018/08/30 13:55
-
Regarding configuring of Data Logging
The CPU module logging feature is accessed from the CPU module logging configuration tool. If the tool is installed, launch it from GX Works3 Tools > Logg... More Details >>
- No:44613
- Release Date:2024/11/28 16:12
-
CC-Link IE field When a network such as Network Basic is interrupted, the CPU module does not stop and continues to run. When the CC-Link IE Field Network i... More Details >>
- No:44611
- Release Date:2024/11/28 16:11
-
Regrading using the Positioning Function with a Relay-Output Type FX5 CPU Module
High-speed pulse I/O module : The FX5-16 ET/ES-H can be added regardless of the output type of the CPU Module, and the positioning function can be used with ... More Details >>
- No:44366
- Release Date:2024/03/27 16:19