Regarding number of input/output points when adding safety extension module
It will. It is treated the same as an intelligent module, so it occupies 8 I/O points. The safety input expansion module FX5-SF-8DI4 does not occupy the numb... More Details >>
- No:39314
- Release Date:2023/01/12 16:54
-
Regarding the system configuration of FX5-CCL-MS with FX5 CPU module
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>
- No:22318
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:50
-
Regarding Data Register Byte Splitting
Use the WTOB instruction. More Details >>
- No:40022
- Release Date:2023/08/24 14:32
-
Regarding the maximum number of connections for MODBUS communication
32 stations can be connected when RS-485 port is used and only 1 station can be connected when RS-232 port is used. More Details >>
- No:22324
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
-
The FX3 intelligent function modules cannot be selected from the Element selection window because it does not correspond to the parameter setting of GX Works... More Details >>
- No:22304
- Release Date:2018/08/30 13:55
- Update:2024/08/19 09:50
-
Regarding program conversion from FX3 Series to iQ-F Series
You can convert an FX3 series project (extension.gxw) to an iQ-F series project by selecting and opening it from the GX Works3 Projects > Open Other Forma... More Details >>
- No:44349
- Release Date:2024/03/27 15:31
-
Regarding differences in simple CPU communication functions
There is no difference in functionality, only in the number of connections. More Details >>
- No:40039
- Release Date:2023/08/24 15:44
-
Regarding nesting contacts displayed on bus by master control instructions
It is not possible. More Details >>
- No:39361
- Release Date:2023/02/15 13:04
-
Regarding using the FX5S CPU module Data Logging Function
SD Memory Card module: You will need an FX5-SDCD and an SD memory card. More Details >>
- No:39333
- Release Date:2023/02/14 09:09
-
Regarding the specifications of the built-in Ethernet function of FX5 CPU module
The connection using the Ethernet port can establish a total of 8 connections which includes SLMP, MELSOFT connection, MODBUS/TCP, socket communication, and ... More Details >>
- No:22320
- Release Date:2018/08/30 13:55
- Update:2023/07/04 15:52