Regarding the parallel link function between CPU modules
Parallel linking between FX5 and FX3 CPU modules is not available. The N:N Network function supports communication between the FX5 CPU module and the FX3 CPU... More Details >>
- No:39364
- Release Date:2023/02/15 13:05
-
Regarding the login screen for the Web Server Function
There is no setting or method to disable the login screen for the web server function. More Details >>
- No:44357
- Release Date:2024/03/27 15:52
-
Regarding using the connector of the CPU Module
The input/output cables used in the FX3GC and FX3UC basic units can be diverted to the FX5UC CPU Module (connector type). More Details >>
- No:44350
- Release Date:2024/03/27 15:44
-
Regarding Boot Operation procedures
The boot operation function is configured and executed from the GX Works3 parameter settings as follows. (1) Open the boot configuration screen. From the... More Details >>
- No:44348
- Release Date:2024/03/27 15:29
-
Regarding use of the FTP Server Auto Transfer Function with Other Functions
Be careful when using the FTP server auto transfer function in combination with the following functions. ・FTP client (FTPPUT instruction) The function exe... More Details >>
- No:44336
- Release Date:2024/03/20 13:28
-
Regarding replacement from 128 point type of FX3U
The FX5U CPU module has a lineup of up to 80 point. The following configuration is recommended when replacing the FX3U-128MR/ES. Recommended alternative (1... More Details >>
- No:44617
- Release Date:2024/11/28 16:13
-
Regarding handling multiple executions of ADPRW Instructions
When multiple ADPRW instructions are simultaneously executed, communication by the ADPRW command that was executed earlier is completed and communication by ... More Details >>
- No:39354
- Release Date:2023/02/15 10:17
-
Regarding clearing error with SM50
It is cleared by eliminating the cause of the error during detection and turning on SM50. For the error codes that can be cleared on the SM50, refer to the ... More Details >>
- No:39292
- Release Date:2023/02/13 15:37
-
Regarding Statement and Note Types
PLC :it is written to the CPU module and consumes the number of steps. ・Without character - 3 steps ・With character : 4 + (Number of characters + 2 + 14) /... More Details >>
- No:40023
- Release Date:2023/08/24 15:39
-
Regarding remote I/O expansion for FX5S CPU module
It is possible to connect to remote I/O with CC-Link IE Field Network Basic. Up to 16 remote stations can be connected. More Details >>
- No:40041
- Release Date:2023/08/24 15:45
- Update:2025/03/13 10:08