FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
It is used for switching between Sink/Source input. For sink input wiring, connect with "24V" terminal and short-circuit the "0V" and "input X***". For sou... More Details >>
- No:22286
- Release Date:2018/08/30 13:55
- Update:2022/12/22 09:39
-
Regarding the type of battery which can be used with the CPU module.
FX3U-32BL can be used. The battery is not included with the CPU modu... More Details >>
- No:22285
- Release Date:2018/08/30 13:55
-
Regrading using the Positioning Function with a Relay-Output Type FX5 CPU Module
High-speed pulse I/O module : The FX5-16 ET/ES-H can be added regardless of the output type of the CPU Module, and the positioning function can be used with ... More Details >>
- No:44366
- Release Date:2024/03/27 16:19
-
By using the Time calculation FB library, you can perform calculations that across years, months and days. In the time calculation FB library, you can add an... More Details >>
- No:44362
- Release Date:2024/03/27 16:03
-
Regarding dedicated instruction for JOG operation
There is no dedicated instruction to drive JOG. Use PLSV (variable speed operation) when operating JOG. More Details >>
- No:44355
- Release Date:2024/03/27 15:50
-
Regarding write speed during RUN
CC-Link IE field Network Basic communication interval can be set with special relay and special register. During debugging, adjust the communication interv... More Details >>
- No:44342
- Release Date:2024/03/20 13:39
-
Regarding automatic transfer of Data Logging Files
Data logging file transfer (FTP server auto transfer) is supported with the following firmware versions. ・FX5U/FX5UC CPU Module Ver. 1.300 or later ・FX5U... More Details >>
- No:44334
- Release Date:2024/03/20 13:30
-
Regarding analog volume support
With the FX5 CPU module , there is no CPU module or option that supports analog volumes. More Details >>
- No:40044
- Release Date:2023/08/24 16:13
-
Regarding I/O expansion for FX5S CPU module
It is possible to increase the number of remote I/O points with CC-Link IE Field Network Basic. Up to 8 remote stations can be connected. More Details >>
- No:40041
- Release Date:2023/08/24 15:45
-
EN (enable input) ・・・ This is the execution condition of the function. The function with EN is executed only if the execution condition of EN... More Details >>
- No:40024
- Release Date:2023/08/24 14:35
121-130 of Total 170