Regarding connection through a MODBUS/TCP Gateway
Communication is possible with simple CPU communication function of FX5CPU, FX5-ENET, FX5-ENET/IP modules. ※FX5U and FX5UC CPU modules with firmware version... More Details >>
- No:39343
- Release Date:2023/01/12 17:05
- Update:2023/06/23 11:13
-
Regarding the frequency of high-speed counters
The maximum frequency of the FX5U/FX5UC CPU module is 200kHz and the maximum frequency of the FX5S/FX5UJ CPU module is 100 kHz. More Details >>
- No:22312
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:18
-
Regarding simulation function using GX Works3
For FX5U/FX5UC CPU modules, GX Works3 Ver. 1.025B or later is supported, and for FX5UJ CPU modules, GX Works3 Ver. 1.065T or later is supported. FX5S CPU mo... More Details >>
- No:22327
- Release Date:2018/08/30 13:55
- Update:2023/02/15 12:56
-
Regarding clearing error with SM50
It is cleared by eliminating the cause of the error during detection and turning on SM50. For the error codes that can be cleared on the SM50, refer to the ... More Details >>
- No:39292
- Release Date:2023/02/13 15:37
-
Regarding converting FBD/LD Projects
It can't be converted. More Details >>
- No:39328
- Release Date:2023/02/14 09:05
-
Regarding the FX5UC CPU module/Intelligent Function module Power Cable
The model name of the power cable is FX2NC-100MPCB. It is included with the FX5UC CPU module and intelligent function modules that require power from the pow... More Details >>
- No:40021
- Release Date:2023/08/24 14:31
-
Regarding SFC Language Support
The FX5 CPU module supports SFC language with the following firmware versions. ・FX5U/FX5UC Ver. 1.220 or later ・FX5UJ Ver. 1.050 or later ・FX5S Ver. 1.010... More Details >>
- No:40043
- Release Date:2023/08/24 15:47
-
Regarding instructions for converting constants from decimal to hexadecimal
Decimal numbers of up to 4 digits can be converted to hexadecimal numbers using the BCD(P) instruction, and decimal numbers of up to 8 digits can be converte... More Details >>
- No:44352
- Release Date:2024/03/27 15:43
-
Regarding I/O assignment on the module configuration diagram of GX Works3
While the module configuration window is being displayed, the I/O assignment can be checked by selecting the following options from the menu bar: [Edit]→[X... More Details >>
- No:22307
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:25
-
Regarding how to clear simple CPU communication function errors
After removing the error factor, you can clear it by executing "Clear latest error code" from "Diagnostic" - "Simple CPU Communication Diagnostic" in GX Work... More Details >>
- No:40049
- Release Date:2023/08/25 09:06