- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding the supported version of the simple CPU communication function
For FX5U/FX5UC CPU module, firmware version 1.110 or later is supported. For the FX5UJ/FX5S CPU module, it is compatible from the first one. More Details >>
- No:39316
- Release Date:2023/02/14 08:56
-
Regarding connection through a MODBUS/TCP Gateway
Communication is possible with simple CPU communication function of FX5CPU, FX5-ENET, FX5-ENET/IP modules. ※FX5U and FX5UC CPU modules with firmware version... More Details >>
- No:39343
- Release Date:2023/01/12 17:05
- Update:2023/06/23 11:13
-
Regarding automatic transfer of Data Logging Files
Data logging file transfer (FTP server auto transfer) is supported with the following firmware versions. ・FX5U/FX5UC CPU Module Ver. 1.300 or later ・FX5U... More Details >>
- No:44334
- Release Date:2024/03/20 13:30
-
Regarding How to release Online Program Change
In GX Works3, [Tools] - [Options] - [Conversion] - [Online Program Change], set "Execute Online Program Change in Converting" to "No." More Details >>
- No:44876
- Release Date:2025/03/18 10:26
-
Regarding expansion of communication ports
MODBUS serial communication over multiple communication channels is possible. The MODBUS serial communication settings can be set from GX Works3 parameters. More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2025/11/11 14:20
-
The FX3 intelligent function modules cannot be selected from the Element selection window because it does not correspond to the parameter setting of GX Works... More Details >>
- No:22304
- Release Date:2018/08/30 13:55
- Update:2024/08/19 09:50
-
Regarding the method to connect with multiple devices via Ethernet port
Multiple connections can be established by using a switching hub. More Details >>
- No:22321
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:26
-
Regarding CC-Link IE Field Network Basic Refresh Settings
You can't. Device allocation for refresh settings is sequential only. More Details >>
- No:39306
- Release Date:2023/02/13 16:41
-
Regarding dedicated instruction for JOG operation
There is no dedicated instruction to drive JOG. Use PLSV (variable speed operation) when operating JOG. More Details >>
- No:44355
- Release Date:2024/03/27 15:50
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
141-150 of Total 185