Regarding dedicated instruction for JOG operation
There is no dedicated instruction to drive JOG. Use PLSV (variable speed operation) when operating JOG. More Details >>
- No:44355
- Release Date:2024/03/27 15:50
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
-
Regarding CC-Link IE Filed Basic Protocol Mixing
It is possible to mix CC-Link IE Filed Basic and general-purpose Ethernet communication. More Details >>
- No:40031
- Release Date:2023/08/24 14:40
-
Regarding the digital output of the built-in analog function
It is possible by setting the scaling function or shift function from the parameter settings. More Details >>
- No:22315
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:46
-
Regarding simulation function using GX Works3
For FX5U/FX5UC CPU modules, GX Works3 Ver. 1.025B or later is supported, and for FX5UJ CPU modules, GX Works3 Ver. 1.065T or later is supported. FX5S CPU mo... More Details >>
- No:22327
- Release Date:2018/08/30 13:55
- Update:2023/02/15 12:56
-
Regarding maximum number of connections for the simple CPU communication function
The maximum number of connections for the simple CPU communication function of FX5 CPU module is 16 for FX5U/FX5UC CPU module and 8 for FX5UJ/FX5S CPU module... More Details >>
- No:40032
- Release Date:2023/08/24 15:37
-
Regarding Control response parameter of built-in PID Control of CPU Module
The control response parameter can set the response to the target value (SV) of PID control as either "normal" or "fast". The difference is as follows. (1)W... More Details >>
- No:44653
- Release Date:2025/03/18 10:23
-
Regarding comparison of Strings
Use the string comparison instructions LD$□, AND$□, OR$□. □contains =, <>, >, < =, <, > =. More Details >>
- No:39355
- Release Date:2023/02/15 13:03
-
Regarding how to generate a false error
There is no function to generate a false error. For example, if operand (s2): divisor is set to "0" in the division command and the command is executed, err... More Details >>
- No:44610
- Release Date:2024/11/28 16:11
-
Regarding number of CC-Link IE field network Basic connections
When the FX5 CPU Module is used as the master station, the maximum number of devices connected to 1 network is 16. The following firmware versions are requi... More Details >>
- No:44652
- Release Date:2025/03/18 10:22