Regarding using the connector of the CPU Module
The input/output cables used in the FX3GC and FX3UC basic units can be diverted to the FX5UC CPU Module (connector type). More Details >>
- No:44350
- Release Date:2024/03/27 15:44
-
Regarding the driving contacts of high-speed counter instructions
The current value of the high-speed counter is retained and will not be cleared. More Details >>
- No:39304
- Release Date:2023/02/13 16:40
-
Regarding protocol mixing in Serial Communication
It is not possible to connect multiple devices with different communication speeds and parities. More Details >>
- No:45480
- Release Date:2025/11/12 13:54
-
Regarding replacing FLT Instructions
For the iQ-F series, use the following instructions. For signed 16 bit integers, use the INT2FLT instruction. For unsigned 16 bit integers, use the UINT2FL... More Details >>
- No:45479
- Release Date:2025/11/12 13:54
-
Regarding Recommended Substitute Models for FX3G-CNV-ADP
The FX5 CPU modules allows you to add an expansion adapter without using a connector conversion adapter. Therefore, there is no Recommended Substitute Models... More Details >>
- No:44875
- Release Date:2025/03/18 10:27
-
Regarding number of CH of CPU Module built-in Heating/Cooling PID control
The CPU Module's built-in Heating/Cooling PID control function supports up to 16 channels. The following firmware versions are required in order to use it. ... More Details >>
- No:44651
- Release Date:2025/03/18 10:22
-
Regarding how to compare multiple word devices
It is possible to compare multiple word devices using the BKCMP_□ instruction. *where □ is the comparison symbol. Example:To compare 10 stores from D0 to D... More Details >>
- No:44616
- Release Date:2024/11/28 16:13
-
Regarding signs of VAL Instructions
The sign is required in the VAL instruction and cannot be ignored. More Details >>
- No:44609
- Release Date:2024/11/28 16:11
-
Regarding restrictions on the external input/output forced ON/OFF function
The following restrictions apply to the external input/output forced ON/OFF function. ・Since RUN contact setting is RUN/STOP by external signal, forced ON/O... More Details >>
- No:44332
- Release Date:2024/03/20 12:58
-
Regarding forced ON/OFF function for external input/output
The "Forced ON/OFF function for external input/output" that forces X/Y devices to turn on/off from GX Works3 is supported with the following firmware version... More Details >>
- No:44330
- Release Date:2024/03/20 12:56