Regarding how to compare multiple word devices
It is possible to compare multiple word devices using the BKCMP_□ instruction. *where □ is the comparison symbol. Example:To compare 10 stores from D0 to D... More Details >>
- No:44616
- Release Date:2024/11/28 16:13
-
Regrading using the Positioning Function with a Relay-Output Type FX5 CPU Module
High-speed pulse I/O module : The FX5-16 ET/ES-H can be added regardless of the output type of the CPU Module, and the positioning function can be used with ... More Details >>
- No:44366
- Release Date:2024/03/27 16:19
-
Regarding write speed during RUN
CC-Link IE field Network Basic communication interval can be set with special relay and special register. During debugging, adjust the communication interv... More Details >>
- No:44342
- Release Date:2024/03/20 13:39
-
Regarding the communication execution status output device for ADPRW instructions
It does not turn OFF automatically. Use the RST command in the program to turn it OFF. More Details >>
- No:39349
- Release Date:2023/02/15 10:07
-
Regarding the possibility of adding an additional module to the FX5S CPU module
You cannot. The FX5S CPU module does not support the connection of an additional module (I/O module, Intelligent function module, FX5 safety extension modul... More Details >>
- No:39339
- Release Date:2023/02/14 17:28
-
Regarding specifications of the forced ON/OFF function for external input/output
The following points are different for the iQ-F series. ・All output disabled flag (SM8034) When SM8034 is ON, the all output disabled flag is given priorit... More Details >>
- No:44331
- Release Date:2024/03/20 12:54
-
Regarding performing Data Logging with Special Relays
It's possible. Using special relays, it is possible to perform data logging from a program. For details, see the manual below. MELSEC iQ-F FX5 User's Manu... More Details >>
- No:39327
- Release Date:2023/02/14 09:05
-
Regarding Extended File Register (ER) file names
File names can not be changed. It is fixed to EXFILER.ERD. More Details >>
- No:39296
- Release Date:2023/02/13 16:39
-
Regarding whether ladder monitoring is enabled by the Web server function
You cannot use the ladder monitor with the Web server function. With the Web server function, it is possible to monitor the device value, test the device (w... More Details >>
- No:44873
- Release Date:2025/03/18 10:23
-
Regarding Bus Conversion Module Differences
The FX5-CNV-BUS is an additional cable type. ・Used when the FX5-CNV-BUS previous module is an expansion cable type module. The FX5-CNV-BUSC is an a... More Details >>
- No:44353
- Release Date:2024/03/27 15:49