- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding whether ladder monitoring is enabled by the Web server function
You cannot use the ladder monitor with the Web server function. With the Web server function, it is possible to monitor the device value, test the device (w... More Details >>
- No:44873
- Release Date:2025/03/18 10:23
-
CC-Link IE field When a network such as Network Basic is interrupted, the CPU module does not stop and continues to run. When the CC-Link IE Field Network i... More Details >>
- No:44611
- Release Date:2024/11/28 16:11
-
Regarding CC-Link IE Filed Basic Protocol Mixing
It is possible to mix CC-Link IE Filed Basic and general-purpose Ethernet communication. More Details >>
- No:40031
- Release Date:2023/08/24 14:40
-
Regarding the possibility of adding an additional module to the FX5S CPU module
You cannot. The FX5S CPU module does not support the connection of an additional module (I/O module, Intelligent function module, FX5 safety extension modul... More Details >>
- No:39339
- Release Date:2023/02/14 17:28
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>
- No:45477
- Release Date:2025/11/12 13:37
-
Regarding reuse of GOT connector cable when replacing with FX5 CPU module
The connection cable is GT01-C30R4-8P. The FX5U CPU module does not have an RS422 port, so you will need to add an FX5-422-BD-GOT. More Details >>
- No:44615
- Release Date:2024/11/28 16:13
-
From the [Module] tab ⇒ [Module FB] in the [Element Selection] window of GX Works3, drag and drop the Module FB you want to use to the program editor. More Details >>
- No:44606
- Release Date:2024/11/28 16:11
-
Regarding program conversion from FX3 Series to iQ-F Series
You can convert an FX3 series project (extension.gxw) to an iQ-F series project by selecting and opening it from the GX Works3 Projects > Open Other Forma... More Details >>
- No:44349
- Release Date:2024/03/27 15:31
-
Regarding use of the FTP Server Auto Transfer Function with Other Functions
Be careful when using the FTP server auto transfer function in combination with the following functions. ・FTP client (FTPPUT instruction) The function exe... More Details >>
- No:44336
- Release Date:2024/03/20 13:28
-
The following points are different for the iQ-F series. ・Error History If the FX5 CPU Module is turned off, the error history is cleared. ・Setting detail... More Details >>
- No:44335
- Release Date:2024/03/20 13:21
161-170 of Total 185