Regarding number of CH of CPU Module built-in Heating/Cooling PID control
The CPU Module's built-in Heating/Cooling PID control function supports up to 16 channels. The following firmware versions are required in order to use it. ... More Details >>
- No:44651
- Release Date:2025/03/18 10:22
-
Regarding replacement from 128 point type of FX3U
The FX5U CPU module has a lineup of up to 80 point. The following configuration is recommended when replacing the FX3U-128MR/ES. Recommended alternative (1... More Details >>
- No:44617
- Release Date:2024/11/28 16:13
-
Regarding checking latch settings
You can find it in the Advanced Settings section of GX Works3. Use the following procedure to display the Device (High Speed) settings. From the GX Wor... More Details >>
- No:44364
- Release Date:2024/03/27 16:05
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
-
Regarding using inline ST in FBD/LD Programs
You can. It is supported by GX Works3 Ver. 1.085P and later. More Details >>
- No:39335
- Release Date:2023/02/14 09:10
-
Regarding program execution using SD Memory Cards
It's possible. Use the boot operation function of the SD memory card. *To use the boot operation function with the FX5S CPU module, you need to install an a... More Details >>
- No:39311
- Release Date:2023/02/14 08:54
-
Regarding the effect of battery voltage drop on logging function
Since the battery retains clock data even after power failure, the time of logging data may change. More Details >>
- No:39310
- Release Date:2023/01/12 16:53
-
Not supported. More Details >>
- No:39305
- Release Date:2023/02/13 16:41
-
Regarding Instruction processing time when the program capacity: 128 K steps are set
LD instruction: 0.35 μs, MOV instruction: 0.779 μs. For other instructions, see the manual below. MELSEC iQ-F FX5 Programming Manual (Instructions, Standa... More Details >>
- No:39362
- Release Date:2023/01/12 17:12
-
Regarding performing Data Logging with Special Relays
It's possible. Using special relays, it is possible to perform data logging from a program. For details, see the manual below. MELSEC iQ-F FX5 User's Manu... More Details >>
- No:39327
- Release Date:2023/02/14 09:05