Regarding connector conversion module differences
The FX5-CNV-IF is an additional cable type. ・FX5U/FX5UJ CPU Modules are supported. ・Used to connect an extension connector type module to an extension ca... More Details >>
- No:44351
- Release Date:2024/03/27 15:45
-
Regarding restrictions on the external input/output forced ON/OFF function
The following restrictions apply to the external input/output forced ON/OFF function. ・Since RUN contact setting is RUN/STOP by external signal, forced ON/O... More Details >>
- No:44332
- Release Date:2024/03/20 12:58
-
Regarding FX5U/FX5UC CPU Module Built-in functions
The functions supported only by the FX5U/FX5UC CPU Modules are listed below. ・Predefined Protocol Support Function For Positioning function ・Optional batte... More Details >>
- No:40046
- Release Date:2023/08/24 16:14
- Update:2024/11/11 14:29
-
Regarding Display Module Support
In the iQ-F series, there is no lineup of display modules. Consider usingweb server function. More Details >>
- No:40045
- Release Date:2023/08/24 15:53
- Update:2023/08/24 15:56
-
Regarding clearing the maximum and minimum scan times
It can be cleared with the scan time clear function. You can clear maximum and minimum scan time with GX Works3 Ver. 1.085 P or later or by special relays. More Details >>
- No:39342
- Release Date:2023/02/15 10:05
-
Regarding "_ U" in Application Instruction
It means an instruction that handles BIN 16 bit and BIN 32 bit unsigned data. Example:ADD _ U More Details >>
- No:39295
- Release Date:2023/02/13 16:37
-
Regarding write speed during RUN
CC-Link IE field Network Basic communication interval can be set with special relay and special register. During debugging, adjust the communication interv... More Details >>
- No:44342
- Release Date:2024/03/20 13:39
-
Regarding performing Data Logging with Special Relays
It's possible. Using special relays, it is possible to perform data logging from a program. For details, see the manual below. MELSEC iQ-F FX5 User's Manu... More Details >>
- No:39327
- Release Date:2023/02/14 09:05
-
Regarding enclosed power cable for input module and input/output module for extension connector type
The FX2NC-100BPCB is included with the following products. CPU Modules: FX5UC-32 MT/D, FX5UC-64 MT/D, FX5UC-96 MT/D More Details >>
- No:40047
- Release Date:2023/08/24 16:30
- Update:2024/05/09 09:59
-
Regarding FX5S CPU module Terminal Block Removal
You can't put it on or take it off. The terminal block of the FX5S CPU module is a non-removable terminal block. More Details >>
- No:39334
- Release Date:2023/02/14 09:10