FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding the compatible programming tool
GX Developer/GX Works2 cannot be used. MELSEC iQ-F series only supports GX Works3. More Details >>
- No:22292
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:34
-
Regarding the method to check the scan time
The current value of the scan time is stored in the following special devices. Please monitor using GX Works3. ◇Scan information SD520 Current scan time (... More Details >>
- No:22289
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:20
-
Regarding EtherCAT Communications
The FX5 CPU module does not support EtherCAT communication. There are no products in the FX series or iQ-F series that support EtherCAT communication. More Details >>
- No:39313
- Release Date:2023/02/14 08:54
-
Regarding the latch settings of data register
It is necessary to set the latch range from the following GX Works3 parameters: [Navigation Window] -> [CPU Parameters] -> [Device/Memory Settings] -&... More Details >>
- No:22329
- Release Date:2018/08/30 13:55
- Update:2024/11/11 13:49
-
It is used for switching between Sink/Source input. For sink input wiring, connect with "24V" terminal and short-circuit the "0V" and "input X***". For sou... More Details >>
- No:22286
- Release Date:2018/08/30 13:55
- Update:2022/12/22 09:39
-
Regarding GX Works3 Module configuration diagram
It can't be configured. In the module configuration diagram of GX Works3, the configurations that can be created are those excluding FX5-CNV-IFC and FX3 Int... More Details >>
- No:39331
- Release Date:2023/02/14 09:08
-
Regarding communication with MX Component
For MX Component Ver.5, Ver. 5.000A or later supports the FX5U/FX5UC/FX5UJ CPU modules, and Ver. 5.003D or later supports the FX5S CPU module. Also, both se... More Details >>
- No:22328
- Release Date:2018/08/30 13:55
- Update:2023/02/15 13:07
-
Regarding MODBUS/TCP communication of the built-in Ethernet port
When used as a master station, communication with a slave station can be performed using the simple CPU communication or the predefined protocol support func... More Details >>
- No:22302
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:52
-
Regarding the cause of communication error with GX Works3
From the PC's Internet Protocol Version 4 Properties, uncheck "Obtain an IP address automatically" option and set an arbitrary IP adress that does not dupli... More Details >>
- No:22319
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:38
-
Regarding FX5 CPU Module clock settings
There are three types of configuration: GX Works3, special devices (SM/SD), and instructions. ・How to Configure in GX Works3 (1) In GX Works3, select On... More Details >>
- No:44365
- Release Date:2024/03/27 17:01
171-180 of Total 185