Regarding the Certificate of non-applicability to export to other countries
For issuance of a certificate, please consult your local Mitsubishi representative. More Details >>
- No:22301
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:15
-
Regarding Online program Change for FX5 CPU module
Ladder program, ST program ・It is supported from the first product. SFC program The following version supports Online program Change. ・FX5U/FX5UC module ... More Details >>
- No:40018
- Release Date:2023/08/24 14:30
-
Regarding the function of a special relay.
SM400 and SM8000. ※FX compatible area(SM8000~, SD8000~) is available for the special relay and special device. More Details >>
- No:22288
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:09
-
Regarding comparison of Strings
Use the string comparison instructions LD$□, AND$□, OR$□. □contains =, <>, >, < =, <, > =. More Details >>
- No:39355
- Release Date:2023/02/15 13:03
-
Regarding communication with MX Component
For MX Component Ver.5, Ver. 5.000A or later supports the FX5U/FX5UC/FX5UJ CPU modules, and Ver. 5.003D or later supports the FX5S CPU module. Also, both se... More Details >>
- No:22328
- Release Date:2018/08/30 13:55
- Update:2023/02/15 13:07
-
Regarding the frequency of high-speed counters
The maximum frequency of the FX5U/FX5UC CPU module is 200kHz and the maximum frequency of the FX5S/FX5UJ CPU module is 100 kHz. More Details >>
- No:22312
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:18
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
-
Regarding swapping upper and lower bytes of string data
You can use the SWAP (P) command to swap the upper and lower bytes of the specified device. More Details >>
- No:44361
- Release Date:2024/03/27 15:55
-
Regarding I/O assignment on the module configuration diagram of GX Works3
While the module configuration window is being displayed, the I/O assignment can be checked by selecting the following options from the menu bar: [Edit]→[X... More Details >>
- No:22307
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:25
-
Regarding instructions for converting constants from decimal to hexadecimal
Decimal numbers of up to 4 digits can be converted to hexadecimal numbers using the BCD(P) instruction, and decimal numbers of up to 8 digits can be converte... More Details >>
- No:44352
- Release Date:2024/03/27 15:43