- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding how to clear simple CPU communication function errors
After removing the error factor, you can clear it by executing "Clear latest error code" from "Diagnostic" - "Simple CPU Communication Diagnostic" in GX Work... More Details >>
- No:40049
- Release Date:2023/08/25 09:06
-
Regarding connection through a MODBUS/TCP Gateway
Communication is possible with simple CPU communication function of FX5CPU, FX5-ENET, FX5-ENET/IP modules. ※FX5U and FX5UC CPU modules with firmware version... More Details >>
- No:39343
- Release Date:2023/01/12 17:05
- Update:2023/06/23 11:13
-
Regarding the supported version of the simple CPU communication function
For FX5U/FX5UC CPU module, firmware version 1.110 or later is supported. For the FX5UJ/FX5S CPU module, it is compatible from the first one. More Details >>
- No:39316
- Release Date:2023/02/14 08:56
-
Regarding the built-in analog input/output function
FX5U CPU module has 2 built-in voltage input channels (DC0~10V) and 1 built-in voltage output channel (DC0~10V). If an external resister is connected, the m... More Details >>
- No:22313
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:47
-
Regarding the Certificate of non-applicability to export to other countries
For issuance of a certificate, please consult your local Mitsubishi representative. More Details >>
- No:22301
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:15
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
-
Regarding Boot Operation procedures
The boot operation function is configured and executed from the GX Works3 parameter settings as follows. (1) Open the boot configuration screen. From the... More Details >>
- No:44348
- Release Date:2024/03/27 15:29
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37
-
Regarding the range of latch devices
The latch range can be set arbitrarily by the customer. The settings can be found in the memory/device settings of CPU parameters. To back up the link regist... More Details >>
- No:22297
- Release Date:2018/08/30 13:55
21-30 of Total 179