- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
The FX3 intelligent function modules cannot be selected from the Element selection window because it does not correspond to the parameter setting of GX Works... More Details >>
- No:22304
- Release Date:2018/08/30 13:55
- Update:2024/08/19 09:50
-
Regarding switching PID instructions for Auto-tuning
It's possible. More Details >>
- No:39320
- Release Date:2023/02/14 09:00
-
Regarding MODBUS/TCP communication of the built-in Ethernet port
When used as a master station, communication with a slave station can be performed using the simple CPU communication or the predefined protocol support func... More Details >>
- No:22302
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:52
-
Regarding the method to check the scan time
The current value of the scan time is stored in the following special devices. Please monitor using GX Works3. ◇Scan information SD520 Current scan time (... More Details >>
- No:22289
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:20
-
It is used for switching between Sink/Source input. For sink input wiring, connect with "24V" terminal and short-circuit the "0V" and "input X***". For sou... More Details >>
- No:22286
- Release Date:2018/08/30 13:55
- Update:2022/12/22 09:39
-
Regarding use of the FTP Server Auto Transfer Function with Other Functions
Be careful when using the FTP server auto transfer function in combination with the following functions. ・FTP client (FTPPUT instruction) The function exe... More Details >>
- No:44336
- Release Date:2024/03/20 13:28
-
Regarding the text color of file names
The data name shown in "red" means "unconverted data" or "unused data before conversion." Data name displayed in 'light blue' means "unused". If a conversio... More Details >>
- No:39345
- Release Date:2023/02/15 10:06
-
"Rebuild All" converts the entire project and "Convet" only coverts the modified part of the program. More Details >>
- No:22326
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:40
-
Regarding the method to connect with multiple devices via Ethernet port
Multiple connections can be established by using a switching hub. More Details >>
- No:22321
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:26
-
Regarding changing the current value of the high-speed counter.
To rewrite the current value, arbitrary values can be written using the DHCMOV instruction. (Example) Set the current value of the high-speed counter ch1 ... More Details >>
- No:22303
- Release Date:2018/08/30 13:55
- Update:2023/02/06 17:05
21-30 of Total 179