Regarding connection through a MODBUS/TCP Gateway
Communication is possible with simple CPU communication function of FX5CPU, FX5-ENET, FX5-ENET/IP modules. ※FX5U and FX5UC CPU modules with firmware version... More Details >>
- No:39343
- Release Date:2023/01/12 17:05
- Update:2023/06/23 11:13
-
Regarding changing the current value of the high-speed counter.
To rewrite the current value, arbitrary values can be written using the DHCMOV instruction. (Example) Set the current value of the high-speed counter ch1 ... More Details >>
- No:22303
- Release Date:2018/08/30 13:55
- Update:2023/02/06 17:05
-
Regarding the necessity of using a battery
Device back up is available without using a battery. However, to back up link register (W) and file register (R) devices, a FX3U-32BL (battery) is required.... More Details >>
- No:22296
- Release Date:2018/08/30 13:55
- Update:2022/12/22 09:55
-
Regarding the supported version of the simple CPU communication function
For FX5U/FX5UC CPU module, firmware version 1.110 or later is supported. For the FX5UJ/FX5S CPU module, it is compatible from the first one. More Details >>
- No:39316
- Release Date:2023/02/14 08:56
-
By using the Time calculation FB library, you can perform calculations that across years, months and days. In the time calculation FB library, you can add an... More Details >>
- No:44362
- Release Date:2024/03/27 16:03
-
Regarding forced ON/OFF function for external input/output
The "Forced ON/OFF function for external input/output" that forces X/Y devices to turn on/off from GX Works3 is supported with the following firmware version... More Details >>
- No:44330
- Release Date:2024/03/20 12:56
-
Regarding protocol creation of Predefined Protocol Support Function
You can not create a protocol for the other device. More Details >>
- No:39293
- Release Date:2023/02/13 15:38
-
Regarding MODBUS Device Allocation Settings
No need. The MODBUS device allocation settings are used when the MODBUS slave function is used. More Details >>
- No:40026
- Release Date:2023/08/24 14:37
-
Regarding printing of cross-references
If cross-references are displayed on GX Works3, you can print them. More Details >>
- No:44619
- Release Date:2024/11/28 16:10
-
Regarding whether ladder monitoring is enabled by the Web server function
You cannot use the ladder monitor with the Web server function. With the Web server function, it is possible to monitor the device value, test the device (w... More Details >>
- No:44873