Regarding using inline ST in FBD/LD Programs
You can. It is supported by GX Works3 Ver. 1.085P and later. More Details >>
- No:39335
- Release Date:2023/02/14 09:10
-
Regarding the procedure for functions set in GX Works3
This is possible with the Guidance flow function. On GX Works3, you can view the setting procedure for the function you want to use. *It is supported by GX ... More Details >>
- No:39341
- Release Date:2023/02/14 17:29
-
Regarding the text color of file names
The data name shown in "red" means "unconverted data" or "unused data before conversion." Data name displayed in 'light blue' means "unused". If a conversio... More Details >>
- No:39345
- Release Date:2023/02/15 10:06
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
-
Regarding MODBUS Device Allocation Settings
No need. The MODBUS device allocation settings are used when the MODBUS slave function is used. More Details >>
- No:40026
- Release Date:2023/08/24 14:37
-
Regarding remote I/O expansion for FX5S CPU module
It is possible to connect to remote I/O with CC-Link IE Field Network Basic. Up to 16 remote stations can be connected. More Details >>
- No:40041
- Release Date:2023/08/24 15:45
- Update:2025/03/13 10:08
-
Regarding Bus Conversion Module Differences
The FX5-CNV-BUS is an additional cable type. ・Used when the FX5-CNV-BUS previous module is an expansion cable type module. The FX5-CNV-BUSC is an a... More Details >>
- No:44353
- Release Date:2024/03/27 15:49
-
Regarding scan time adjustment for replacing the FX3 Series
You can adjust by setting the constant scan in iQ-F series. Setting procedure: Navigation window > [Parameter] > [Module model name] > [CPU Paramet... More Details >>
- No:44866
- Release Date:2025/03/18 10:24
-
Regarding CC-Link IE field network support of FX5 CPU module built-in Ethernet
The built-in Ethernet on the FX5 CPU module does not support CC-Link IE field networks. If you use a CC-Link IE field network, add an FX5-CCLIEF. *The FX5-... More Details >>
- No:44877
- Release Date:2025/03/18 10:30
-
Regarding KeepAlive for SLMP Communication
For TCP protocol of SLMP communication, KeepAlive is fixed and cannot be changed. In the case of UDP protocol, it is fixed to not perform a keep-alive check. More Details >>
- No:45477
- Release Date:2025/11/12 13:37