FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding double-precision real numbers
The FX5 CPU unit does not handle double-precision real numbers. Only single-precision real numbers can be handled. More Details >>
- No:40033
- Release Date:2023/08/24 15:37
-
Regarding restrictions on the external input/output forced ON/OFF function
The following restrictions apply to the external input/output forced ON/OFF function. ・Since RUN contact setting is RUN/STOP by external signal, forced ON/O... More Details >>
- No:44332
- Release Date:2024/03/20 12:58
-
Regarding initialization procedure
From GXWorks3, use [Online] -[CPU Memory Operation] to initialize. How to check the IP address is as follows. They are stored in special registers SD8492 a... More Details >>
- No:45481
- Release Date:2025/11/12 13:54
-
The FX5 CPU module does not support UDP broadcast communication. More Details >>
- No:22291
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
-
Regarding CW/CCW(Forward pulse/Reverse pulse) output of the built-in positioning function
FX5U/FX5UC/FX5S CPU modules are supported. Up to 2 axes are available in GX Works3 parameter settings. In addition, up to 8 axes can be added by adding a hi... More Details >>
- No:22306
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:48
-
Regarding expansion of communication ports
MODBUS serial communication over multiple communication channels is possible. The MODBUS serial communication settings can be set from GX Works3 parameters. More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2025/11/11 14:20
-
Regarding simulation function using GX Works3
For FX5U/FX5UC CPU modules, GX Works3 Ver. 1.025B or later is supported, and for FX5UJ CPU modules, GX Works3 Ver. 1.065T or later is supported. FX5S CPU mo... More Details >>
- No:22327
- Release Date:2018/08/30 13:55
- Update:2023/02/15 12:56
-
Regarding converting FBD/LD Projects
It can't be converted. More Details >>
- No:39328
- Release Date:2023/02/14 09:05
-
Regarding the procedure for functions set in GX Works3
This is possible with the Guidance flow function. On GX Works3, you can view the setting procedure for the function you want to use. *It is supported by GX ... More Details >>
- No:39341
- Release Date:2023/02/14 17:29
-
Regarding connector conversion module differences
The FX5-CNV-IF is an additional cable type. ・FX5U/FX5UJ CPU Modules are supported. ・Used to connect an extension connector type module to an extension ca... More Details >>
- No:44351
- Release Date:2024/03/27 15:45