Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
-
Regarding dedicated instruction for JOG operation
There is no dedicated instruction to drive JOG. Use PLSV (variable speed operation) when operating JOG. More Details >>
- No:44355
- Release Date:2024/03/27 15:50
-
Regarding address change of positioning operation.
It can be changed. For example, with the positioning instruction, a word device can be assigned to the operand which specifies the positioning address and t... More Details >>
- No:22298
- Release Date:2018/08/30 13:55
- Update:2023/02/14 09:53
-
Regarding the built-in analog input/output function
FX5U CPU module has 2 built-in voltage input channels (DC0~10V) and 1 built-in voltage output channel (DC0~10V). If an external resister is connected, the m... More Details >>
- No:22313
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:47
-
Regarding Open/Close Socket Communications
No need. More Details >>
- No:39288
- Release Date:2023/02/13 15:36
-
Regarding clearing error with SM50
It is cleared by eliminating the cause of the error during detection and turning on SM50. For the error codes that can be cleared on the SM50, refer to the ... More Details >>
- No:39292
- Release Date:2023/02/13 15:37
-
Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38
-
Regarding the text color of file names
The data name shown in "red" means "unconverted data" or "unused data before conversion." Data name displayed in 'light blue' means "unused". If a conversio... More Details >>
- No:39345
- Release Date:2023/02/15 10:06
-
It represents the number of characters that can be written. By changing "(32)," you can write up to 255 characters. More Details >>
- No:39353
- Release Date:2023/02/15 10:07
-
Regarding I/O expansion for FX5S CPU module
It is possible to increase the number of remote I/O points with CC-Link IE Field Network Basic. Up to 8 remote stations can be connected. More Details >>
- No:40041
- Release Date:2023/08/24 15:45
61-70 of Total 158