- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
-
Regarding the settings of built-in analog function of FX5U CPU module
The settings can be done using the parameter settings of GX Works3 or by settings the special relay/special registers. For further details please refer to M... More Details >>
- No:22314
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:20
-
Regarding swapping upper and lower bytes of string data
You can use the SWAP (P) command to swap the upper and lower bytes of the specified device. More Details >>
- No:44361
- Release Date:2024/03/27 15:55
-
Regarding clearing error with SM50
It is cleared by eliminating the cause of the error during detection and turning on SM50. For the error codes that can be cleared on the SM50, refer to the ... More Details >>
- No:39292
- Release Date:2023/02/13 15:37
-
Regarding communication supported by built-in RS-485 port
N:N Network, Parallel Link, MC protocol, Non-protocol communication, MELSOFT connection, MODBUS RTU, and Predefined protocol support are available. More Details >>
- No:22322
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:16
-
Regarding the system configuration of FX5-CCL-MS with FX5 CPU module
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>
- No:22318
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:50
-
Regarding speed change of positioning operation.
It can be changed. For details, please refer to MELSEC iQ-F FX5 User's Manual (Positioning Control - CPU module built-in, high speed pulse input/output modu... More Details >>
- No:22299
- Release Date:2018/08/30 13:55
- Update:2023/02/14 09:52
-
The FX5 CPU module does not support UDP broadcast communication. More Details >>
- No:22291
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
-
Regarding remote I/O expansion for FX5S CPU module
It is possible to connect to remote I/O with CC-Link IE Field Network Basic. Up to 16 remote stations can be connected. More Details >>
- No:40041
- Release Date:2023/08/24 15:45
- Update:2025/03/13 10:08
-
Regarding number of input/output points when adding safety extension module
It will. It is treated the same as an intelligent module, so it occupies 8 I/O points. The safety input expansion module FX5-SF-8DI4 does not occupy the numb... More Details >>
- No:39314
- Release Date:2023/01/12 16:54