It is not possible to convert to GX Works2 format. More Details >>
- No:39326
- Release Date:2023/02/14 09:03
-
Regarding clearing the maximum and minimum scan times
It can be cleared with the scan time clear function. You can clear maximum and minimum scan time with GX Works3 Ver. 1.085 P or later or by special relays. More Details >>
- No:39342
- Release Date:2023/02/15 10:05
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
-
Regarding changing the current address (user unit, pulse unit)
It can be changed. It is now possible to write to the address (user unit, pulse unit) by the DHCMOV command. However, writing is disabled during positioning... More Details >>
- No:39356
- Release Date:2023/02/15 13:03
-
Regarding differences between 8 bit and 16 bit modes for non-protocol communication
In 8-bit mode, the upper 8 bits of transmitted and received data are ignored and only the lower 8 bits are valid data. In 16 bit mode, send/receive data i... More Details >>
- No:39363
- Release Date:2023/02/15 13:04
-
Regarding configuring of Data Logging
The CPU module logging feature is accessed from the CPU module logging configuration tool. If the tool is installed, launch it from GX Works3 Tools > Logg... More Details >>
- No:44613
- Release Date:2024/11/28 16:12
-
Regarding reading Sample Comments for Expansion Adapters
You cannot. The expansion adapters does not support reading sample comments. More Details >>
- No:39352
- Release Date:2023/02/15 10:16
-
Regarding remote I/O expansion for FX5S CPU module
It is possible to connect to remote I/O with CC-Link IE Field Network Basic. Up to 16 remote stations can be connected. More Details >>
- No:40041
- Release Date:2023/08/24 15:45
- Update:2025/03/13 10:08
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
-
Regarding the login screen for the Web Server Function
There is no setting or method to disable the login screen for the web server function. More Details >>
- No:44357
- Release Date:2024/03/27 15:52