Regarding reading Sample Comments for Expansion Adapters
You cannot. The expansion adapters does not support reading sample comments. More Details >>
- No:39352
- Release Date:2023/02/15 10:16
-
Regarding the parallel link function between CPU modules
Parallel linking between FX5 and FX3 CPU modules is not available. The N:N Network function supports communication between the FX5 CPU module and the FX3 CPU... More Details >>
- No:39364
- Release Date:2023/02/15 13:05
-
Regarding Device Memory Export/Import
Imports are not supported. Only exports are supported. More Details >>
- No:40027
- Release Date:2023/08/24 14:38
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
-
Regarding the line tracing function
It is not supported. More Details >>
- No:39323
- Release Date:2023/02/14 09:01
-
Regarding double-precision real numbers
The FX5 CPU unit does not handle double-precision real numbers. Only single-precision real numbers can be handled. More Details >>
- No:40033
- Release Date:2023/08/24 15:37
-
Regarding settings when the battery is installed
From the GX Works3 settings when the optional battery is installed, it must be set to Installed in the Optional Battery Settings. Use the following proc... More Details >>
- No:44363
- Release Date:2024/03/27 17:09
-
Regrading using the Positioning Function with a Relay-Output Type FX5 CPU Module
High-speed pulse I/O module : The FX5-16 ET/ES-H can be added regardless of the output type of the CPU Module, and the positioning function can be used with ... More Details >>
- No:44366
- Release Date:2024/03/27 16:19
-
From the following menu of GX Works3: [Diagnostics]→[Module Diagnostics(CPU Diagnostics)] the event history function can be found. The event history can dis... More Details >>
- No:22305
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:37
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37