FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > Engineering Software
FAQ
Keyword Search
FAQ within [ Engineering Software ]
-
Regarding the line tracing function
It is not supported. More Details >>
- No:39323
- Release Date:2023/02/14 09:01
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
-
Regarding converting FBD/LD Projects
It can't be converted. More Details >>
- No:39328
- Release Date:2023/02/14 09:05
-
Regarding clearing the maximum and minimum scan times
It can be cleared with the scan time clear function. You can clear maximum and minimum scan time with GX Works3 Ver. 1.085 P or later or by special relays. More Details >>
- No:39342
- Release Date:2023/02/15 10:05
-
Regarding the differences between Latches (1) and (2)
Whether the latch range is set by default is different. ・Latch (1) — Latch range is set by default. This can be changed at any time. ・Latch (2) — No latch ... More Details >>
- No:39351
- Release Date:2023/02/15 13:08
- Update:2024/08/19 09:54
-
Regarding how to format an SD memory card
In GX Works3, go to Online > CPU Memory Operation, select "SD Memory Card" and execute "Initialization." More Details >>
- No:39344
- Release Date:2023/02/15 10:03
-
By using the Time calculation FB library, you can perform calculations that across years, months and days. In the time calculation FB library, you can add an... More Details >>
- No:44362
- Release Date:2024/03/27 16:03
-
Regarding the compatible programming tool
GX Developer/GX Works2 cannot be used. MELSEC iQ-F series only supports GX Works3. More Details >>
- No:22292
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:34
-
Regarding signs of VAL Instructions
The sign is required in the VAL instruction and cannot be ignored. More Details >>
- No:44609
- Release Date:2024/11/28 16:11
-
Regarding simulation function using GX Works3
For FX5U/FX5UC CPU modules, GX Works3 Ver. 1.025B or later is supported, and for FX5UJ CPU modules, GX Works3 Ver. 1.065T or later is supported. FX5S CPU mo... More Details >>
- No:22327
- Release Date:2018/08/30 13:55
- Update:2023/02/15 12:56