FAQ
![](/usr/file/attachment/q&a.jpg)
![](/usr/file/attachment/q&a_sp.jpg)
FAQAbout Products
![](/usr/file/attachment/img_mv-1_sm.jpg)
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > Network/Communication
FAQ
Keyword Search
FAQ within [ Network/Communication ]
-
Regarding how to check MAC Addresses
You can check the MAC address from the name plate on the side of the CPU module or by the Module diagnostics (CPU diagnostics) of GX Works3. More Details >>
- No:39294
- Release Date:2023/02/13 15:37
-
Regarding the default IP address
The default IP address (factory default value) of FX5CPU modules is 192.168.3.250. More Details >>
- No:22290
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:33
-
Regarding how to change the IP address
The IP address can be changed from a program by using the IP address change function. The IP address change function can change the IP address, subnet mask,... More Details >>
- No:39332
- Release Date:2023/02/14 09:09
- Update:2024/08/19 09:52
-
Regarding EtherCAT Communications
The FX5 CPU module does not support EtherCAT communication. There are no products in the FX series or iQ-F series that support EtherCAT communication. More Details >>
- No:39313
- Release Date:2023/02/14 08:54
-
Regarding the Certificate of non-applicability to export to other countries
For issuance of a certificate, please consult your local Mitsubishi representative. More Details >>
- No:22301
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:15
-
Regarding simultaneous execution of the MQTT communication function
The MQTT communication function cannot publish and subscribe at the same time. A program for the MQTT communication function is created using FB, but it c... More Details >>
- No:44345
- Release Date:2024/03/27 15:25
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37
-
Regarding MODBUS/TCP communication of the built-in Ethernet port
When used as a master station, communication with a slave station can be performed using the simple CPU communication or the predefined protocol support func... More Details >>
- No:22302
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:52
-
Regarding connecting to AWS IoT Core Using the TCP Protocol
Because the AWS IoT Core specification is the TLS protocol, you cannot connect using the TCP protocol. More Details >>
- No:44344
- Release Date:2024/03/20 13:37
-
Regarding setting the FX5 CPU Module that does not support the simple CPU communication function
When connecting 2 FX5 CPU Modules (firmware version 1.110 or later) that support the Simple CPU communication function and 2 FX5 CPU Modules (firmware vers... More Details >>
- No:44329
- Release Date:2024/03/20 13:35
1-10 of Total 95