Regarding MODBUS/TCP communication of the built-in Ethernet port
When used as a master station, communication with a slave station can be performed using the simple CPU communication or the predefined protocol support func... More Details >>
- No:22302
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:52
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
-
Regarding communication supported by built-in RS-485 port
N:N Network, Parallel Link, MC protocol, Non-protocol communication, MELSOFT connection, MODBUS RTU, and Predefined protocol support are available. More Details >>
- No:22322
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:16
-
Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
-
Regarding the maximum number of connections for MODBUS communication
32 stations can be connected when RS-485 port is used and only 1 station can be connected when RS-232 port is used. More Details >>
- No:22324
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
-
Regarding the connection between FX5-CCLGN-MS and NZ2GN2S-60AD4
Available. More Details >>
- No:39279
- Release Date:2023/01/12 16:47
-
Regarding the connection between FX5-CCLGN-MS and SLMP-compatible devices
The SLMP communication frames supported by the FX5-CCLGN-MS are 3E and 4E frames. When SLMP communication is performed from an SLMP-compatible device to the... More Details >>
- No:39280
- Release Date:2023/01/12 16:48
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
1-10 of Total 97