Regarding TPDO and RPDO allocation
RWr is allocated to TPDO and RWw is allocated to RPDO. More Details >>
- No:44479
- Release Date:2024/07/02 19:06
-
Regarding protocol mixing in Serial Communication
It is not possible to connect multiple devices with different communication speeds and parities. More Details >>
- No:45480
- Release Date:2025/11/12 13:54
-
Regarding EtherNet/IP communication function for FX5-EIP
The following EtherNet/IP communication functions are supported by the FX5-EIP. ・Cyclic communication function ⇒Class1 instance communication/tag communicat... More Details >>
- No:45483
- Release Date:2025/11/12 13:55
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
-
Regarding FX5-ENET/IP parameter settings
You will need the EtherNet/IP Configuration Tool for FX5-ENET/IP. Download the tool from the FA site. More Details >>
- No:39302
- Release Date:2023/01/12 16:53
-
Regarding QoS, Retain, Will, and Clean Session Functions for MQTT Communications
The QoS, Retain, Will, and Clean Session functions of the MQTT communication function can not be configured in buffer memory. Module FB: M+FX5ENET. QoS ca... More Details >>
- No:40053
- Release Date:2023/08/25 09:21
-
Regarding communication testing of Certificate Configuration Tool for FX5-ENET
The following are possible causes for communication not being established between the Certificate Configuration Tool for FX5-ENET and FX5-ENET. (1) Connecte... More Details >>
- No:40075
- Release Date:2023/08/25 09:06
-
Regarding features of EtherNet/IP Communication
Class1 communication sends and receives data at regular intervals. It is mainly used for I/O communication and motion control between PLC and sensor. Class... More Details >>
- No:45485
- Release Date:2025/11/12 13:55
-
Regarding CC-Link IE Filed Basic Protocol Mixing
It is possible to mix CC-Link IE Filed Basic and general-purpose Ethernet communication. More Details >>
- No:40031
- Release Date:2023/08/24 14:40