- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > Network/Communication
FAQ
Keyword Search
FAQ within [ Network/Communication ]
-
Regarding the connection between FX5-CCLGN-MS and inverter
FX5-CCLGN-MS supports 1 Gbps communication speed with firmware version: 1.010, and 1 Gbps and 100 Mbps communication speed for version 1.010. If the communi... More Details >>
- No:39281
- Release Date:2023/01/12 16:48
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
-
The batch setting of PDO mapping sets the default PDO mapping for all device stations that support PDO mapping. *Note that in the batch setting of PDO mappi... More Details >>
- No:44476
- Release Date:2024/07/02 19:06
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
-
Regarding differences between 8 bit and 16 bit modes for non-protocol communication
In 8-bit mode, the upper 8 bits of transmitted and received data are ignored and only the lower 8 bits are valid data. In 16 bit mode, send/receive data i... More Details >>
- No:39363
- Release Date:2023/02/15 13:04
-
Regarding maximum number of connections for MQTT communication function
The MQTT communication function can be used for up to one connection. More Details >>
- No:40055
- Release Date:2023/08/25 08:53
-
Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
-
Regarding the data link program of FX5-CCL-MS
Since the FX5-CCL-MS has a link refresh setting, there is no need for a program to read and write data to each station. More Details >>
- No:44614
- Release Date:2024/11/28 16:12
-
Regarding Tag communication support of FX5-ENET/IP
Class1 communication of FX5-ENET/IP is instance communication. Tag communication is not supported. More Details >>
- No:44624
- Release Date:2024/11/28 16:14
-
Regarding CC-Link IE Field Network Station Type
Local stations can obtain information about all device stations. Intelligent device stations can only obtain information about their own stations. FX5-CCLI... More Details >>
- No:39301
- Release Date:2023/01/12 16:52